Creep failure characteristics in P23/P91 dissimilar welds
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25870807%3A_____%2F10%3A%230000209" target="_blank" >RIV/25870807:_____/10:#0000209 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Creep failure characteristics in P23/P91 dissimilar welds
Popis výsledku v původním jazyce
Two variants of P23/P91 heterogeneous welds were studied. The composition of filler material in Weld A corresponded to that of P91 steel, whilst for Weld B the low alloy filler material of P23 type composition was used. Results of creep rupture tests onthe cross weld specimens are close to, or slightly below, the lower limit of the 20% scatter band around the standardized curve for creep strength of the P23 steel. Creep rupture tests were performed at temperatures of 500, 550 and 600°C with time to rupture up to 60 000hours. Optical microscopy investigations and hardness measurements were carried out on longitudinal sections through ruptured cross weld specimens in order to reveal the effect of testing parameters (temperature, stress) on the preferredlocation of creep failure. It has been found that in both weld variants creep damage can develop simultaneously in several parts of the cross-weld specimens.
Název v anglickém jazyce
Creep failure characteristics in P23/P91 dissimilar welds
Popis výsledku anglicky
Two variants of P23/P91 heterogeneous welds were studied. The composition of filler material in Weld A corresponded to that of P91 steel, whilst for Weld B the low alloy filler material of P23 type composition was used. Results of creep rupture tests onthe cross weld specimens are close to, or slightly below, the lower limit of the 20% scatter band around the standardized curve for creep strength of the P23 steel. Creep rupture tests were performed at temperatures of 500, 550 and 600°C with time to rupture up to 60 000hours. Optical microscopy investigations and hardness measurements were carried out on longitudinal sections through ruptured cross weld specimens in order to reveal the effect of testing parameters (temperature, stress) on the preferredlocation of creep failure. It has been found that in both weld variants creep damage can develop simultaneously in several parts of the cross-weld specimens.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proc. of 19th International Conference on Metallurgy and Materials, Metal 2010
ISBN
978-80-87294-17-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
TANGER s.r.o.
Místo vydání
Ostrava
Místo konání akce
Rožnov pod Radhoštěm
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—