Fracture Toughness Characterisation of the Martensitic Chromium Steel P91
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26316919%3A_____%2F12%3A%230000349" target="_blank" >RIV/26316919:_____/12:#0000349 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.comat.cz/files/proceedings/11/reports/1244.pdf" target="_blank" >http://www.comat.cz/files/proceedings/11/reports/1244.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fracture Toughness Characterisation of the Martensitic Chromium Steel P91
Popis výsledku v původním jazyce
In this paper J-R curves were measured with Charpy size SE(B) and C(T) specimens of P91 steel using the unloading compliance technique. The fracture toughness parameters were determined according to the test standards ASTM E1820 and ISO 12135 and whose evaluation differences and validity criteria were assessed. Despite the available sophisticated instrumentation used for obtaining the J-R curves and strict implementation of the recommended test procedure, a scatter in the initial portion of the curve ispersistent. This creates problems in the evaluation of the measured J-?a values and in obtaining valid and unambiguous JIC and J0.2BL values according to both standards. The influence of these scatter on the fracture toughness values is discussed. Accompanying fractographic studies were performed to assess the J-R curves and to determine the SZW.
Název v anglickém jazyce
Fracture Toughness Characterisation of the Martensitic Chromium Steel P91
Popis výsledku anglicky
In this paper J-R curves were measured with Charpy size SE(B) and C(T) specimens of P91 steel using the unloading compliance technique. The fracture toughness parameters were determined according to the test standards ASTM E1820 and ISO 12135 and whose evaluation differences and validity criteria were assessed. Despite the available sophisticated instrumentation used for obtaining the J-R curves and strict implementation of the recommended test procedure, a scatter in the initial portion of the curve ispersistent. This creates problems in the evaluation of the measured J-?a values and in obtaining valid and unambiguous JIC and J0.2BL values according to both standards. The influence of these scatter on the fracture toughness values is discussed. Accompanying fractographic studies were performed to assess the J-R curves and to determine the SZW.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI2%2F279" target="_blank" >FR-TI2/279: *Identifikace parametrů tvárného porušení materiálů jaderných zařízení</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
COMAT 2012
ISBN
978-80-87294-34-5
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
TANGER spol. s r.o., CZ
Místo vydání
Ostrava, CZ
Místo konání akce
Plzeň
Datum konání akce
21. 11. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—