Influence of sandblasting and acid etching on fatigue properties of ultra-fine grained Ti grade 4 for dental implants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26316919%3A_____%2F20%3AN0000022" target="_blank" >RIV/26316919:_____/20:N0000022 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1751616120305671" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1751616120305671</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2020.104016" target="_blank" >10.1016/j.jmbbm.2020.104016</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of sandblasting and acid etching on fatigue properties of ultra-fine grained Ti grade 4 for dental implants
Popis výsledku v původním jazyce
Commercially pure Ti is a typical material for dental implants. Besides oral environmental effects, implants are seriously mechanically loaded during the lifetime. Mechanical resistance of coarse and ultra-fine grained Ti grade 4 was investigated. Significant grain size refinement resulting in the 65% increase of the proof stress is reported. The fatigue endurance limit increased from 523 MPa to 698 MPa due to grain refinement. The influence of sandblasting combined with acid etching on fatigue damage of both material states was analyzed. The surface treatment was proven as detrimental to the fatigue properties of both material states, due to reduction of the fatigue initiation stage. Nevertheless, the fatigue endurance limit of the surface-treated ultra-fine grained material remained higher than the fatigue endurance limit of the coarse-grained material without surface treatment. Reported results confirm better mechanical resistance of ultra-fine grained materials for dental implants in the comparison with coarse-grain one.
Název v anglickém jazyce
Influence of sandblasting and acid etching on fatigue properties of ultra-fine grained Ti grade 4 for dental implants
Popis výsledku anglicky
Commercially pure Ti is a typical material for dental implants. Besides oral environmental effects, implants are seriously mechanically loaded during the lifetime. Mechanical resistance of coarse and ultra-fine grained Ti grade 4 was investigated. Significant grain size refinement resulting in the 65% increase of the proof stress is reported. The fatigue endurance limit increased from 523 MPa to 698 MPa due to grain refinement. The influence of sandblasting combined with acid etching on fatigue damage of both material states was analyzed. The surface treatment was proven as detrimental to the fatigue properties of both material states, due to reduction of the fatigue initiation stage. Nevertheless, the fatigue endurance limit of the surface-treated ultra-fine grained material remained higher than the fatigue endurance limit of the coarse-grained material without surface treatment. Reported results confirm better mechanical resistance of ultra-fine grained materials for dental implants in the comparison with coarse-grain one.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1412" target="_blank" >LO1412: Rozvoj Západočeského materiálově metalurgického Centra</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
ISSN
1751-6161
e-ISSN
1878-0180
Svazek periodika
111
Číslo periodika v rámci svazku
Listopad 2020
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
18
Strana od-do
nestránkováno
Kód UT WoS článku
000575377200004
EID výsledku v databázi Scopus
2-s2.0-85089275388