Fatigue properties of UFG Ti grade 2 dental implant vs. conventionally tested smooth specimens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26316919%3A_____%2F21%3AN0000022" target="_blank" >RIV/26316919:_____/21:N0000022 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081723:_____/21:00544713 RIV/00216305:26620/21:PU141951
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S175161612100374X" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S175161612100374X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2021.104715" target="_blank" >10.1016/j.jmbbm.2021.104715</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fatigue properties of UFG Ti grade 2 dental implant vs. conventionally tested smooth specimens
Popis výsledku v původním jazyce
Complicated geometry in combination with surface treatment strongly deteriorates fatigue resistance of metallic dental implants. Mechanical properties of pure Ti grade 2, usually used for dental implant production, were shown to be significantly improved due to intensive grain refinement via Conform SPD. The increase of the tensile strength properties was accompanied by a significant increase in the fatigue resistance and fatigue endurance limit. However, the SLA treatment usually used for the implants' surface roughening, resulted in the fatigue properties and endurance limit decrease, while this effect was more pronounced for the ultrafine-grained comparing to the coarse-grained material when tested under tensile-tensile loading mode. The testing of the implants is usually provided under the bending mode. Even though different testing condition for the conventional specimens tests and implants testing was adopted, a numerical study revealed their comparable fatigue properties. The fatigue limit determined for the implants was 105% higher than the one for coarse-grained and only by 4 % lower than the one for ultrafine-grained Ti grade 2. Based on the obtained results, conventional specimens testing can be used for the prediction of the fatigue limit of the implants.
Název v anglickém jazyce
Fatigue properties of UFG Ti grade 2 dental implant vs. conventionally tested smooth specimens
Popis výsledku anglicky
Complicated geometry in combination with surface treatment strongly deteriorates fatigue resistance of metallic dental implants. Mechanical properties of pure Ti grade 2, usually used for dental implant production, were shown to be significantly improved due to intensive grain refinement via Conform SPD. The increase of the tensile strength properties was accompanied by a significant increase in the fatigue resistance and fatigue endurance limit. However, the SLA treatment usually used for the implants' surface roughening, resulted in the fatigue properties and endurance limit decrease, while this effect was more pronounced for the ultrafine-grained comparing to the coarse-grained material when tested under tensile-tensile loading mode. The testing of the implants is usually provided under the bending mode. Even though different testing condition for the conventional specimens tests and implants testing was adopted, a numerical study revealed their comparable fatigue properties. The fatigue limit determined for the implants was 105% higher than the one for coarse-grained and only by 4 % lower than the one for ultrafine-grained Ti grade 2. Based on the obtained results, conventional specimens testing can be used for the prediction of the fatigue limit of the implants.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
ISSN
1751-6161
e-ISSN
1878-0180
Svazek periodika
123
Číslo periodika v rámci svazku
NOV 2021
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
nestránkováno
Kód UT WoS článku
000703875400004
EID výsledku v databázi Scopus
2-s2.0-85111842299