Horizontal channel for neutron radiography and tomography in LVR-15 research reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F12%3A%230000707" target="_blank" >RIV/26722445:_____/12:#0000707 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Horizontal channel for neutron radiography and tomography in LVR-15 research reactor
Popis výsledku v původním jazyce
The LVR-15 reactor is a light water research reactor, which is situated in Nuclear Centre Řež Ltd., Řež near Prague. The reactor operates as a multipurpose facility with maximal thermal power of 10 MW. It has ten horizontal channels. One of them, not used up to now, is prepared for neutron transmission radiography and tomography. The method is based on absorption and scatter of thermal neutrons in the analysed sample. The channel leads neutrons from the reactor core with 3 m long and 100 mm in diametertube. For the neutron radiography, collimated beam of thermal neutrons is necessary to prepare. Around the irradiation box, shielding for gamma and neutron radiation will be used for radiation protection purposes. Measurement of neutron fluence in the beam outlet with free channel is presented. Measurement results are compared with MCNP calculations. Next calculations of neutron fluence and gamma dose rate were made for design of filters inside the channel and shielding around the irradi
Název v anglickém jazyce
Horizontal channel for neutron radiography and tomography in LVR-15 research reactor
Popis výsledku anglicky
The LVR-15 reactor is a light water research reactor, which is situated in Nuclear Centre Řež Ltd., Řež near Prague. The reactor operates as a multipurpose facility with maximal thermal power of 10 MW. It has ten horizontal channels. One of them, not used up to now, is prepared for neutron transmission radiography and tomography. The method is based on absorption and scatter of thermal neutrons in the analysed sample. The channel leads neutrons from the reactor core with 3 m long and 100 mm in diametertube. For the neutron radiography, collimated beam of thermal neutrons is necessary to prepare. Around the irradiation box, shielding for gamma and neutron radiation will be used for radiation protection purposes. Measurement of neutron fluence in the beam outlet with free channel is presented. Measurement results are compared with MCNP calculations. Next calculations of neutron fluence and gamma dose rate were made for design of filters inside the channel and shielding around the irradi
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010237" target="_blank" >TA01010237: Pracoviště pro nedestruktivní testování, diagnostiku a 3D zobrazování pomocí neutronové radiografie a tomografie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
RRFM Transactions, Prague, Czech Republic, 18-22 March 2012
ISBN
978-92-95064-13-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
638-642
Název nakladatele
European Nuclear Society
Místo vydání
Brussels, Belgium
Místo konání akce
Praha
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—