Measurement of thermal neutron beam parameters in the LVR-15 research reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F13%3A%230000787" target="_blank" >RIV/26722445:_____/13:#0000787 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of thermal neutron beam parameters in the LVR-15 research reactor
Popis výsledku v původním jazyce
Proceedings of the Joint IGORR and IAEA technical meeting, October 13-18, 2013, Daejeon, Korea. The LVR-15 research reactor, situated at the site of the Research Centre Řež near Prague, is equipped with ten horizontal channels. In 2012, into one of thema special filter was mounted and a radiation shielding box was established around the channel in order to take preparations for a future neutron transmission radiography and tomography facility. Basic beam parameters comprise neutron fluence rate and spectrum, and spatial thermal neutron distribution (beam divergence). These parameters were measured with activation detectors and a silicon detector with a 6Li converter. In addition, the gamma dose rate at the channel outlet was measured using TLD dosimeters. The measured thermal neutron fluence rate was determined at the value of about 2x108 cm-2.s-1 and beam homogeneity was proclaimed acceptable at a diameter of 100 mm for the future neutron radiography facility. The results were discus
Název v anglickém jazyce
Measurement of thermal neutron beam parameters in the LVR-15 research reactor
Popis výsledku anglicky
Proceedings of the Joint IGORR and IAEA technical meeting, October 13-18, 2013, Daejeon, Korea. The LVR-15 research reactor, situated at the site of the Research Centre Řež near Prague, is equipped with ten horizontal channels. In 2012, into one of thema special filter was mounted and a radiation shielding box was established around the channel in order to take preparations for a future neutron transmission radiography and tomography facility. Basic beam parameters comprise neutron fluence rate and spectrum, and spatial thermal neutron distribution (beam divergence). These parameters were measured with activation detectors and a silicon detector with a 6Li converter. In addition, the gamma dose rate at the channel outlet was measured using TLD dosimeters. The measured thermal neutron fluence rate was determined at the value of about 2x108 cm-2.s-1 and beam homogeneity was proclaimed acceptable at a diameter of 100 mm for the future neutron radiography facility. The results were discus
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010237" target="_blank" >TA01010237: Pracoviště pro nedestruktivní testování, diagnostiku a 3D zobrazování pomocí neutronové radiografie a tomografie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů