Fuel inspections at Temelín NPP and the root causes study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F12%3A%230000713" target="_blank" >RIV/26722445:_____/12:#0000713 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.euronuclear.org/events/topfuel/topfuel2012/transactions/Transactions-oral.pdf" target="_blank" >http://www.euronuclear.org/events/topfuel/topfuel2012/transactions/Transactions-oral.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fuel inspections at Temelín NPP and the root causes study
Popis výsledku v původním jazyce
Post Irradiation Inspection Program was specified, and different inspections were done to get large amount of data from the bow, twist and growth measurements. In several years many data were measured, root causes were found, and many recomendations fornew fuel design were applied. All the fuel changes and PIIP led to the successful operation with VV-6 fuel assemblies. The IRI issues, as well as the fuel assembly bow and twist were removed in 2005, and the leaking FAs due to GRF were minimized. These fuel operational problems have made a big lesson, and this experience is now prepared to use on the new TVSA-T fuel in fuel operation, as well as fuel inspection and repair.
Název v anglickém jazyce
Fuel inspections at Temelín NPP and the root causes study
Popis výsledku anglicky
Post Irradiation Inspection Program was specified, and different inspections were done to get large amount of data from the bow, twist and growth measurements. In several years many data were measured, root causes were found, and many recomendations fornew fuel design were applied. All the fuel changes and PIIP led to the successful operation with VV-6 fuel assemblies. The IRI issues, as well as the fuel assembly bow and twist were removed in 2005, and the leaking FAs due to GRF were minimized. These fuel operational problems have made a big lesson, and this experience is now prepared to use on the new TVSA-T fuel in fuel operation, as well as fuel inspection and repair.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
TopFuel 2012: Reactor Fuel Performance Transactions
ISBN
978-92-95064-16-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
140-144
Název nakladatele
European Nuclear Society
Místo vydání
Brussels, Belgium
Místo konání akce
Manchester, Great Britain
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce