Innovation of Irradiation Equipment at the LVR-15 Nuclear Research Reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F17%3AN0000022" target="_blank" >RIV/26722445:_____/17:N0000022 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1115/1.4032599" target="_blank" >http://dx.doi.org/10.1115/1.4032599</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1115/1.4032599" target="_blank" >10.1115/1.4032599</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Innovation of Irradiation Equipment at the LVR-15 Nuclear Research Reactor
Popis výsledku v původním jazyce
This paper describes the design and use of a new irradiation facility for the LVR-15 nuclear research reactor. The CHOUCA MT irradiation rig was produced in France according to a design of the UJV Group (UJV Rez and Research Center Rez). There are six heating sections situated along the rig, each instrumented and controlled by its own thermocouple. The rig's insulation layers ensure a balanced temperature in irradiated specimens along its entire length. The specimen holder is 55.9 mm in diameter and 320 mm long. The CHOUCA MT rig can be repetitively irradiated in different positions within the reactor core, depending on irradiation condition requirements. The CHOUCA MT rig expands the possibilities of radiation research in the UJV Group.
Název v anglickém jazyce
Innovation of Irradiation Equipment at the LVR-15 Nuclear Research Reactor
Popis výsledku anglicky
This paper describes the design and use of a new irradiation facility for the LVR-15 nuclear research reactor. The CHOUCA MT irradiation rig was produced in France according to a design of the UJV Group (UJV Rez and Research Center Rez). There are six heating sections situated along the rig, each instrumented and controlled by its own thermocouple. The rig's insulation layers ensure a balanced temperature in irradiated specimens along its entire length. The specimen holder is 55.9 mm in diameter and 320 mm long. The CHOUCA MT rig can be repetitively irradiated in different positions within the reactor core, depending on irradiation condition requirements. The CHOUCA MT rig expands the possibilities of radiation research in the UJV Group.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0108" target="_blank" >ED2.1.00/03.0108: Udržitelná energetika</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Nuclear Engineering and Radiation Science
ISSN
2332-8983
e-ISSN
2332-8975
Svazek periodika
3
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
1-6