Study of fluence and dose spatial distributions in phantoms with various shapes exposed to epithermal neutrons for NCT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F18%3AN0000039" target="_blank" >RIV/26722445:_____/18:N0000039 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radmeas.2018.08.013" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2018.08.013</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2018.08.013" target="_blank" >10.1016/j.radmeas.2018.08.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of fluence and dose spatial distributions in phantoms with various shapes exposed to epithermal neutrons for NCT
Popis výsledku v původním jazyce
The various dose components generated by epithermal neutron beams in tissue-equivalent materials have different spatial distributions that also depend on the size and volume of the irradiated volume. NCT dosimetry requires the separate determination of dose components having different LET, because of their different RBE. Monte Carlo simulations have been developed concerning the absorbed doses and thermal neutron fluences, to investigate the extent of the differences that may occur by changing the shape and size of the irradiated volumes. Moreover, the doses and fluences that occur if specific isotopes (B-10, N-14 Gd-157) are added to water have been evaluated.
Název v anglickém jazyce
Study of fluence and dose spatial distributions in phantoms with various shapes exposed to epithermal neutrons for NCT
Popis výsledku anglicky
The various dose components generated by epithermal neutron beams in tissue-equivalent materials have different spatial distributions that also depend on the size and volume of the irradiated volume. NCT dosimetry requires the separate determination of dose components having different LET, because of their different RBE. Monte Carlo simulations have been developed concerning the absorbed doses and thermal neutron fluences, to investigate the extent of the differences that may occur by changing the shape and size of the irradiated volumes. Moreover, the doses and fluences that occur if specific isotopes (B-10, N-14 Gd-157) are added to water have been evaluated.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1603" target="_blank" >LQ1603: Výzkum pro SUSEN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
119
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
12-15
Kód UT WoS článku
000453491700003
EID výsledku v databázi Scopus
2-s2.0-85052437062