A Dosimetric and Biological Model for Neutron Capture Therapy (NCT) Experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F25%3AN0000013" target="_blank" >RIV/26722445:_____/25:N0000013 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0969804325005780" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0969804325005780</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2025.112233" target="_blank" >10.1016/j.apradiso.2025.112233</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Dosimetric and Biological Model for Neutron Capture Therapy (NCT) Experiments
Popis výsledku v původním jazyce
A hybrid Monte Carlo approach using MCNP in combination with the cell-level code Monte Carlo Damage Simulation (MCDS) is presented to support the design and analysis of experiments for the evaluation of gadolinium (Gd) based agents in neutron capture therapy (NCT). Monoenergetic neutrons (0.025 eV–15 MeV) and polyenergetic neutron beams from NEUTRA, ICON (PSI, Switzerland), and HK1 (LVR-15, Czech Republic) were used to estimate the relative biological effectiveness (RBE) of NCT for the biologically critical endpoint of DNA double strand break (DSB) production relative to 60Co γ-rays. Moreover, microdosimetric spectra of protons, electrons, alpha particles and heavy recoils were determined for the aforementioned neutron beams, to enhance the interpretation of energy deposition in subcellular structrures. The proposed, hybrid model and methodology builds on well-validated dosimetry and biophysical models at different spatial scales to create a versatile and generalized framework to estimate dosimetric parameters and RBE. This approach facilitates comparisons between NCT and low linear energy transfer (LET) radiation alternatives.
Název v anglickém jazyce
A Dosimetric and Biological Model for Neutron Capture Therapy (NCT) Experiments
Popis výsledku anglicky
A hybrid Monte Carlo approach using MCNP in combination with the cell-level code Monte Carlo Damage Simulation (MCDS) is presented to support the design and analysis of experiments for the evaluation of gadolinium (Gd) based agents in neutron capture therapy (NCT). Monoenergetic neutrons (0.025 eV–15 MeV) and polyenergetic neutron beams from NEUTRA, ICON (PSI, Switzerland), and HK1 (LVR-15, Czech Republic) were used to estimate the relative biological effectiveness (RBE) of NCT for the biologically critical endpoint of DNA double strand break (DSB) production relative to 60Co γ-rays. Moreover, microdosimetric spectra of protons, electrons, alpha particles and heavy recoils were determined for the aforementioned neutron beams, to enhance the interpretation of energy deposition in subcellular structrures. The proposed, hybrid model and methodology builds on well-validated dosimetry and biophysical models at different spatial scales to create a versatile and generalized framework to estimate dosimetric parameters and RBE. This approach facilitates comparisons between NCT and low linear energy transfer (LET) radiation alternatives.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
1872-9800
Svazek periodika
226
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
001597077200001
EID výsledku v databázi Scopus
2-s2.0-105018318882