A tool for a spacer material and ion-exchange membrane compatibility evaluation for electrodialysis module design
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F28676092%3A_____%2F17%3AN0000061" target="_blank" >RIV/28676092:_____/17:N0000061 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24220/18:00009706
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A tool for a spacer material and ion-exchange membrane compatibility evaluation for electrodialysis module design
Popis výsledku v původním jazyce
Electrodialysis is a widely used separation process for wastewater treatment, concentration of valuable products or production of organic acids. However, unwanted phenomena can occur during the operation of electrodialysis stacks such as internal leakage and/or external leak. In this study, a new simple tool is presented for testing materials suitable for use as spacers used in ED. This cell for testing leaks simulates ED stack and therefore allowing external leaks to be tested. Regarding tests results suitable materials for an ED scale-up can be chosen. Tests were done for three different pressures (1.5, 2 and 2.5 bar) and three different temperatures (25, 40 and 60 °C). To maintain the same conditions, the test cell was tightened by defined force in the range of 850 to 870 N. In the testing stack different combinations of membrane, and spacers were tested. It was found that with increasing temperature leaks decrease. Parameters that influence external leaks most are surface roughness, texture a hardness of ion-exchange membrane and spacer material.
Název v anglickém jazyce
A tool for a spacer material and ion-exchange membrane compatibility evaluation for electrodialysis module design
Popis výsledku anglicky
Electrodialysis is a widely used separation process for wastewater treatment, concentration of valuable products or production of organic acids. However, unwanted phenomena can occur during the operation of electrodialysis stacks such as internal leakage and/or external leak. In this study, a new simple tool is presented for testing materials suitable for use as spacers used in ED. This cell for testing leaks simulates ED stack and therefore allowing external leaks to be tested. Regarding tests results suitable materials for an ED scale-up can be chosen. Tests were done for three different pressures (1.5, 2 and 2.5 bar) and three different temperatures (25, 40 and 60 °C). To maintain the same conditions, the test cell was tightened by defined force in the range of 850 to 870 N. In the testing stack different combinations of membrane, and spacers were tested. It was found that with increasing temperature leaks decrease. Parameters that influence external leaks most are surface roughness, texture a hardness of ion-exchange membrane and spacer material.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1418" target="_blank" >LO1418: Progresivní rozvoj Membránového inovačního centra</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Periodica Polytechnica Chemical Engineering
ISSN
0324-5853
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
6
Strana od-do
144-149
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85042486251