A Tool for a Spacer Material and Ion-exchange Membrane Compatibility Evaluation for Electrodialysis Module Design
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F18%3A00009706" target="_blank" >RIV/46747885:24220/18:00009706 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/28676092:_____/17:N0000061
Výsledek na webu
<a href="https://pp.bme.hu/ch/article/view/10465" target="_blank" >https://pp.bme.hu/ch/article/view/10465</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3311/PPch.10465" target="_blank" >10.3311/PPch.10465</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Tool for a Spacer Material and Ion-exchange Membrane Compatibility Evaluation for Electrodialysis Module Design
Popis výsledku v původním jazyce
Eleclrodialysis is a widely used separation process for waste-water treatment, concentration of valuable products or production of organic acids. However, unwanted phenomena can occur during the operation of electrodialysis stacks such as internal leakage and/or external leak. In this study, a new simple tool is presented for testing materials suitable for use as spacers used in ED. This cell for testing leaks simulates ED stack and therefore allowing external leaks to be tested. Regarding tests results suitable materials for an ED scale-up can be chosen. Tests were done for three different pressures (1.5, 2 and 2.5 bar) and three different temperatures (25, 40 and 60 degrees C). To maintain the same conditions, the test cell was tightened by defined force in the range of 850 to 870 N. In the testing stack different combinations of membrane, and spacers were tested. It was found that with increasing temperature leaks decrease. Parameters that influence external leaks most are surface roughness, texture a hardness of ion-exchange membrane and spacer material.
Název v anglickém jazyce
A Tool for a Spacer Material and Ion-exchange Membrane Compatibility Evaluation for Electrodialysis Module Design
Popis výsledku anglicky
Eleclrodialysis is a widely used separation process for waste-water treatment, concentration of valuable products or production of organic acids. However, unwanted phenomena can occur during the operation of electrodialysis stacks such as internal leakage and/or external leak. In this study, a new simple tool is presented for testing materials suitable for use as spacers used in ED. This cell for testing leaks simulates ED stack and therefore allowing external leaks to be tested. Regarding tests results suitable materials for an ED scale-up can be chosen. Tests were done for three different pressures (1.5, 2 and 2.5 bar) and three different temperatures (25, 40 and 60 degrees C). To maintain the same conditions, the test cell was tightened by defined force in the range of 850 to 870 N. In the testing stack different combinations of membrane, and spacers were tested. It was found that with increasing temperature leaks decrease. Parameters that influence external leaks most are surface roughness, texture a hardness of ion-exchange membrane and spacer material.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20401 - Chemical engineering (plants, products)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING
ISSN
0324-5853
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
6
Strana od-do
144-149
Kód UT WoS článku
000432753600003
EID výsledku v databázi Scopus
2-s2.0-85042486251