Stability development during healing of immediately loaded dental implants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44265786%3A_____%2F09%3A%230000004" target="_blank" >RIV/44265786:_____/09:#0000004 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stability development during healing of immediately loaded dental implants
Popis výsledku v původním jazyce
To investigate the parameters that can affect the primary stability of dental implants, to find out, how the primary stability influences the post-healing stability and to ascertain the effect of primary stability and insertion parameters on marginal bone loss. In this study, total of 940 immediately functionally loaded implants in the mandibular interforaminal region were considered. Using the resonance frequency analysis, the primary stability (pISQ) and stability after 4 months (tISQ) were recorded.This study demonstrated that: (a) The stability of immediately loaded implants with high primary stability significantly decreased, however, the stability of implants with low primary stability significantly increased during initial 4 months of healing. (b)Implants with primary stability 68-72ISQ maintained their stability during healing phase. (c) DISQ and insertion torque showed significant correlation with marginal bone loss.
Název v anglickém jazyce
Stability development during healing of immediately loaded dental implants
Popis výsledku anglicky
To investigate the parameters that can affect the primary stability of dental implants, to find out, how the primary stability influences the post-healing stability and to ascertain the effect of primary stability and insertion parameters on marginal bone loss. In this study, total of 940 immediately functionally loaded implants in the mandibular interforaminal region were considered. Using the resonance frequency analysis, the primary stability (pISQ) and stability after 4 months (tISQ) were recorded.This study demonstrated that: (a) The stability of immediately loaded implants with high primary stability significantly decreased, however, the stability of implants with low primary stability significantly increased during initial 4 months of healing. (b)Implants with primary stability 68-72ISQ maintained their stability during healing phase. (c) DISQ and insertion torque showed significant correlation with marginal bone loss.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FI-IM5%2F218" target="_blank" >FI-IM5/218: *Výzkum a vývoj nového endosteálního implantátu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Název statě ve sborníku
Clinacal oral implants research
ISBN
—
ISSN
0905-7161
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Wiley-Blackwell
Místo vydání
Malaysia
Místo konání akce
Monaco
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—