<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85068392258&origin=resultslist&sort=plf-f&src=s&st1=Low+pressure+EGR+valve+testing+&st2=&sid=6dc71927694d0289a005ca9471fe76b2&sot=b&sdt=b&sl=46&s=TITLE-ABS-KEY%28Low+pressure+EGR+valve+testing+%29&relpos=0&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85068392258&origin=resultslist&sort=plf-f&src=s&st1=Low+pressure+EGR+valve+testing+&st2=&sid=6dc71927694d0289a005ca9471fe76b2&sot=b&sdt=b&sl=46&s=TITLE-ABS-KEY%28Low+pressure+EGR+valve+testing+%29&relpos=0&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5114768" target="_blank" >10.1063/1.5114768</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Low pressure EGR valve testing
Popis výsledku v původním jazyce
This article deals with testing the low pressure EGR valve and its testing system. The low-pressure EGR valve is part of a flue gas recirculation system that serves to reduce the resulting emissions of internal combustion engines. The flue gas recirculation system consists of a low and high pressure section. A new measuring system is designed to replace the old measuring system. The reason for designing the new system is to reduce costs and reduce space requirements. The entire system is vacuum and can be used for different parts of the flue gas recirculation system. For example, for a high pressure EGR valve or a flue gas exhaust flap.
Název v anglickém jazyce
Low pressure EGR valve testing
Popis výsledku anglicky
This article deals with testing the low pressure EGR valve and its testing system. The low-pressure EGR valve is part of a flue gas recirculation system that serves to reduce the resulting emissions of internal combustion engines. The flue gas recirculation system consists of a low and high pressure section. A new measuring system is designed to replace the old measuring system. The reason for designing the new system is to reduce costs and reduce space requirements. The entire system is vacuum and can be used for different parts of the flue gas recirculation system. For example, for a high pressure EGR valve or a flue gas exhaust flap.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
38th Meeting of Departments of Fluid Mechanics and Thermomechanics
ISBN
978-0-7354-1858-5
ISSN
1551-7616
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
American Institute of Physics
Místo vydání
New York
Místo konání akce
Liptovský Mikuláš
Datum konání akce
19. 6. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—