Smartphone-Based Data Acquisition Method for Modelling 3D Printed Arm Casts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13420%2F23%3A43898097" target="_blank" >RIV/44555601:13420/23:43898097 - isvavai.cz</a>
Výsledek na webu
<a href="https://journalmt.com/artkey/mft-202302-0006_smartphone-based-data-acquisition-method-for-modelling-3d-printed-arm-casts.php" target="_blank" >https://journalmt.com/artkey/mft-202302-0006_smartphone-based-data-acquisition-method-for-modelling-3d-printed-arm-casts.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21062/mft.2023.019" target="_blank" >10.21062/mft.2023.019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Smartphone-Based Data Acquisition Method for Modelling 3D Printed Arm Casts
Popis výsledku v původním jazyce
In recent years, 3D printed arm casts can replace traditional arm casts to treat bones fractures. 3D printed arm cast modelling often uses professional 3D scanning systems to capture 3D data of the arm. These systems are very expensive and may not be available in many hospitals. In order to overcome this disadvantage, inexpensive methods should be developed. This paper introduces a new data collection method based on smartphones. The photos of an arm were taken with a smartphone camera using some special techniques that could facilitate the process of image processing and 3D modelling in Agisoft Metashape and CATIA. To validate the proposed method, the photogrammetric model was compared with the scanned model (obtained by a low cost scanner) in GOM Inspect. Besides, a fit check of real 3D printed arm casts attached on the volunteer's forearm was also performed. The test results indicate that the photogrammetric model could be used as raw data for 3D arm modelling.
Název v anglickém jazyce
Smartphone-Based Data Acquisition Method for Modelling 3D Printed Arm Casts
Popis výsledku anglicky
In recent years, 3D printed arm casts can replace traditional arm casts to treat bones fractures. 3D printed arm cast modelling often uses professional 3D scanning systems to capture 3D data of the arm. These systems are very expensive and may not be available in many hospitals. In order to overcome this disadvantage, inexpensive methods should be developed. This paper introduces a new data collection method based on smartphones. The photos of an arm were taken with a smartphone camera using some special techniques that could facilitate the process of image processing and 3D modelling in Agisoft Metashape and CATIA. To validate the proposed method, the photogrammetric model was compared with the scanned model (obtained by a low cost scanner) in GOM Inspect. Besides, a fit check of real 3D printed arm casts attached on the volunteer's forearm was also performed. The test results indicate that the photogrammetric model could be used as raw data for 3D arm modelling.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
2787-9402
Svazek periodika
23
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
260-267
Kód UT WoS článku
000975659300015
EID výsledku v databázi Scopus
2-s2.0-85159016347