Accuracy of Photogrammetric Models for 3D printed Wrist-hand Orthoses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13420%2F24%3A43898792" target="_blank" >RIV/44555601:13420/24:43898792 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.webofscience.com/wos/woscc/full-record/WOS:001265606800013" target="_blank" >https://www.webofscience.com/wos/woscc/full-record/WOS:001265606800013</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21062/mft.2024.048" target="_blank" >10.21062/mft.2024.048</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accuracy of Photogrammetric Models for 3D printed Wrist-hand Orthoses
Popis výsledku v původním jazyce
Today, 3D printed wrist-hand orthoses can be used to immobilize the arms instead of plaster or fiberglass casts. Typically, 3D arm models for modelling wrist-hand orthoses can be created using a 3D scanning system. Our previous study shows that smartphone cameras and photogrammetry techniques can be used instead of professional 3D scanning systems, but the accuracy of the photogrammetric models has not yet been fully investigated. This paper presents the results of accuracy verification of arm models reconstructed from 2D images captured with a smartphone camera. The forearm and wrist-hand parts of a photogrammetric model were subjected to a virtual inspection by comparing them with the corresponding parts of an arm model created with a 3D scanner. In addition, a physical verification was carried out by assessing the contact between the arm of interest and an actual 3D printed wrist-hand orthosis that was created with reference to the photogrammetric model. The test results show that the photogrammetric models achieve the necessary accuracy to serve as reference models for the construction of 3D printed wrist-hand orthoses.
Název v anglickém jazyce
Accuracy of Photogrammetric Models for 3D printed Wrist-hand Orthoses
Popis výsledku anglicky
Today, 3D printed wrist-hand orthoses can be used to immobilize the arms instead of plaster or fiberglass casts. Typically, 3D arm models for modelling wrist-hand orthoses can be created using a 3D scanning system. Our previous study shows that smartphone cameras and photogrammetry techniques can be used instead of professional 3D scanning systems, but the accuracy of the photogrammetric models has not yet been fully investigated. This paper presents the results of accuracy verification of arm models reconstructed from 2D images captured with a smartphone camera. The forearm and wrist-hand parts of a photogrammetric model were subjected to a virtual inspection by comparing them with the corresponding parts of an arm model created with a 3D scanner. In addition, a physical verification was carried out by assessing the contact between the arm of interest and an actual 3D printed wrist-hand orthosis that was created with reference to the photogrammetric model. The test results show that the photogrammetric models achieve the necessary accuracy to serve as reference models for the construction of 3D printed wrist-hand orthoses.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20202 - Communication engineering and systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
2787-9402
Svazek periodika
24
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
458-464
Kód UT WoS článku
001265606800013