A Successful Case of TKA With Complex Deformity And Retained Hardware Using Computer Navigation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13450%2F22%3A43896653" target="_blank" >RIV/44555601:13450/22:43896653 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2352344121002193" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2352344121002193</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.artd.2021.11.005" target="_blank" >10.1016/j.artd.2021.11.005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Successful Case of TKA With Complex Deformity And Retained Hardware Using Computer Navigation
Popis výsledku v původním jazyce
We present a case report of a 60-year-old Caucasian female patient, who had undergone a series of procedures for a periprosthetic (after total hip arthroplasty) Vancouver C type diaphyseal fracture of the right femur (reverse distal femoral locking compression plate [LCP] osteosynthesis, then a corrective osteotomy with another distal femoral LCP osteosynthesis). Subsequently, she developed high-grade osteoarthrosis of the right knee, indicated for a total knee arthroplasty. Considering the extent of previous procedures, which had significantly compromised the bone quality of the femur and therefore increased the risk of a refracture after an eventual hardware removal, we decided to retain the LCP plate. We concluded that the optimal solution would be the use of a computer-navigated total knee arthroplasty. This procedure obviated the need for intramedullary guiding, while ensuring optimal joint alignment. No postoperative complications emerged.
Název v anglickém jazyce
A Successful Case of TKA With Complex Deformity And Retained Hardware Using Computer Navigation
Popis výsledku anglicky
We present a case report of a 60-year-old Caucasian female patient, who had undergone a series of procedures for a periprosthetic (after total hip arthroplasty) Vancouver C type diaphyseal fracture of the right femur (reverse distal femoral locking compression plate [LCP] osteosynthesis, then a corrective osteotomy with another distal femoral LCP osteosynthesis). Subsequently, she developed high-grade osteoarthrosis of the right knee, indicated for a total knee arthroplasty. Considering the extent of previous procedures, which had significantly compromised the bone quality of the femur and therefore increased the risk of a refracture after an eventual hardware removal, we decided to retain the LCP plate. We concluded that the optimal solution would be the use of a computer-navigated total knee arthroplasty. This procedure obviated the need for intramedullary guiding, while ensuring optimal joint alignment. No postoperative complications emerged.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30230 - Other clinical medicine subjects
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Arthroplasty Today
ISSN
2352-3441
e-ISSN
—
Svazek periodika
neuveden
Číslo periodika v rámci svazku
13
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
29-34
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—