A comparative analysis of four implants used to treat a supracondylar periprosthetic fracture of ostheoporotic femur
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23210%2F19%3A43956990" target="_blank" >RIV/49777513:23210/19:43956990 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/49777513:23520/19:43956990 RIV/49777513:23640/19:43956990
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparative analysis of four implants used to treat a supracondylar periprosthetic fracture of ostheoporotic femur
Popis výsledku v původním jazyce
The fracture in the extra-articular part of distal femur with total knee arthroplasty (TKA) occurs mostly in the elderly patients with ostheoporotic bones. Four implants used for management of such fracture are tested in this study: Distal Femoral Nail (DFN), Locking Compression Plate (LCP), Angled Blade Plate (ABP) and Dynamic Compression Screw (DCS). Each one is integrated into a finite element model of femur with implemented TKA and material properties of an ostheoporotic bone. A simple extra-articular fracture is modelled in the distal part of femur. The femoral head is exposed to axial load and torque. Von Mises stress distributions in the implants and the displacement of femur are analysed to find out whether there is a significant difference among the implants.
Název v anglickém jazyce
A comparative analysis of four implants used to treat a supracondylar periprosthetic fracture of ostheoporotic femur
Popis výsledku anglicky
The fracture in the extra-articular part of distal femur with total knee arthroplasty (TKA) occurs mostly in the elderly patients with ostheoporotic bones. Four implants used for management of such fracture are tested in this study: Distal Femoral Nail (DFN), Locking Compression Plate (LCP), Angled Blade Plate (ABP) and Dynamic Compression Screw (DCS). Each one is integrated into a finite element model of femur with implemented TKA and material properties of an ostheoporotic bone. A simple extra-articular fracture is modelled in the distal part of femur. The femoral head is exposed to axial load and torque. Von Mises stress distributions in the implants and the displacement of femur are analysed to find out whether there is a significant difference among the implants.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů