Modified biosensor for cholinesterase inhibitors with Guinea Green B as the colour indicator
Popis výsledku v původním jazyce
Colorimetric biosensors of cholinesterase inhibitors are ideal for fast, reliable and very simple detection of agents in air, in water and on surfaces. This paper describes an innovation of the Czech Detehit biosensor, which is based on a biochemical enzymatic reaction visualised by using Ellman’s reagent as a chromogenic indicator. The modification basically consists of a much more distinct colour response of the biosensor, attained through optimisation of the reaction system by using Guinea Green B as the indicator. The performance of the modified biosensor was verified on the chemical warfare agents (sarin, soman, cyclosarin and VX) in water. The detection limits ascertained visually (with the naked eye) were about 0.001 µg/mL in water (exposure time 60 seconds, inhibition efficiency 25%).
Název v anglickém jazyce
Modified biosensor for cholinesterase inhibitors with Guinea Green B as the colour indicator
Popis výsledku anglicky
Colorimetric biosensors of cholinesterase inhibitors are ideal for fast, reliable and very simple detection of agents in air, in water and on surfaces. This paper describes an innovation of the Czech Detehit biosensor, which is based on a biochemical enzymatic reaction visualised by using Ellman’s reagent as a chromogenic indicator. The modification basically consists of a much more distinct colour response of the biosensor, attained through optimisation of the reaction system by using Guinea Green B as the indicator. The performance of the modified biosensor was verified on the chemical warfare agents (sarin, soman, cyclosarin and VX) in water. The detection limits ascertained visually (with the naked eye) were about 0.001 µg/mL in water (exposure time 60 seconds, inhibition efficiency 25%).
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20152018024" target="_blank" >VI20152018024: NOVÉ TECHNOLOGIE PRO OSOBNÍ DETEKTOR INHIBITORŮ CHOLINESTERÁZ</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosensors2018
ISSN
2079-6374
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
81-90
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—