Measuring Upper Extremity Loading in Passive Exoskeleton-Assisted Gait: A Case Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46709002%3A_____%2F25%3AN000053" target="_blank" >RIV/46709002:_____/25:N000053 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/11062949" target="_blank" >https://ieeexplore.ieee.org/document/11062949</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICORR66766.2025.11062949" target="_blank" >10.1109/ICORR66766.2025.11062949</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measuring Upper Extremity Loading in Passive Exoskeleton-Assisted Gait: A Case Study
Popis výsledku v původním jazyce
This study investigates upper extremity loading during exoskeleton-assisted walking with the UNILEXA passive exoskeleton using an instrumented platform walker. The goal was to assess upper limb weight-bearing and its implications for rehabilitation. Data were collected from two participants performing walking and standing tasks. During steady walking, the average vertical load on the walker was approximately 30% of body weight, while standing maneuvers showed peaks up to 90%. These results demostrate that, despite the passive nature of the UNILEXA exoskleleton, upper extremity loading remains within acceptable limits, suggesting its suitability for safe and effective rehabilitation.
Název v anglickém jazyce
Measuring Upper Extremity Loading in Passive Exoskeleton-Assisted Gait: A Case Study
Popis výsledku anglicky
This study investigates upper extremity loading during exoskeleton-assisted walking with the UNILEXA passive exoskeleton using an instrumented platform walker. The goal was to assess upper limb weight-bearing and its implications for rehabilitation. Data were collected from two participants performing walking and standing tasks. During steady walking, the average vertical load on the walker was approximately 30% of body weight, while standing maneuvers showed peaks up to 90%. These results demostrate that, despite the passive nature of the UNILEXA exoskleleton, upper extremity loading remains within acceptable limits, suggesting its suitability for safe and effective rehabilitation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2025 International Conference On Rehabilitation Robotics
ISBN
979-8-3503-8068-2
ISSN
1945-7898
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1455-1460
Název nakladatele
IEEE
Místo vydání
USA
Místo konání akce
Chicago USA
Datum konání akce
1. 1. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—