MEASUREMENT OF THE IMPUSLIVE FORCE GENERATED BY COLAPSING BUBBLE CLOSE TO A SOLID BOUNDARY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F12%3A%230002717" target="_blank" >RIV/46747885:24210/12:#0002717 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/epjconf/20122501058" target="_blank" >http://dx.doi.org/10.1051/epjconf/20122501058</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201225010" target="_blank" >10.1051/epjconf/201225010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MEASUREMENT OF THE IMPUSLIVE FORCE GENERATED BY COLAPSING BUBBLE CLOSE TO A SOLID BOUNDARY
Popis výsledku v původním jazyce
The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power leddiode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.
Název v anglickém jazyce
MEASUREMENT OF THE IMPUSLIVE FORCE GENERATED BY COLAPSING BUBBLE CLOSE TO A SOLID BOUNDARY
Popis výsledku anglicky
The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power leddiode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F10%2F1428" target="_blank" >GAP101/10/1428: Mechanizmy kolapsu a štěpení ultrazvukem buzených kavitačních bublin v blízkosti pevné stěny v Newtonské kapalině</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EPJ Web of Conferences
ISSN
2100-014X
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
25
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
6
Strana od-do
"01058-p.1"-"01058-p.6"
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—