Measurement of the impulsive force generated by colapsing bubble close to a solid boundary
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F11%3A00367963" target="_blank" >RIV/61388998:_____/11:00367963 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of the impulsive force generated by colapsing bubble close to a solid boundary
Popis výsledku v původním jazyce
The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power leddiode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.
Název v anglickém jazyce
Measurement of the impulsive force generated by colapsing bubble close to a solid boundary
Popis výsledku anglicky
The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power leddiode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F10%2F1428" target="_blank" >GAP101/10/1428: Mechanizmy kolapsu a štěpení ultrazvukem buzených kavitačních bublin v blízkosti pevné stěny v Newtonské kapalině</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference Experimental Fluid Mechanics 2011
ISBN
978-80-7372-784-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
309-314
Název nakladatele
TU Liberec
Místo vydání
Liberec
Místo konání akce
Jičín
Datum konání akce
22. 11. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—