The effect of the window temperature on the thermal comfort in a room heated by a floor convector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F14%3A00000343" target="_blank" >RIV/46747885:24210/14:00000343 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The effect of the window temperature on the thermal comfort in a room heated by a floor convector
Popis výsledku v původním jazyce
The objective of this paper is the prediction of the surface temperature at a window with a prescribed heat flux, and how it affect the thermal comfort conditions in the space. The negative heat flux here represents the heat loss through a window. The temperature distribution at the window surface is a result of the interaction between a hot air jet and the cooled window surface. The temperature field at the window was determined by measurements using an infrared camera. The measurements were compared with CFD results. The k-epsilon RNG and k-omega turbulence modes were used for CFD simulation to classify the sensitivity of the temperature distribution on the turbulence model and the heat loss magnitude. Two directions and velocities of the hot air flux are compared. The calculation based on the k-omega turbulence model provided constant temperature distribution for wide range of heat fluxes. Results of the k-epsilon RNG model revealed the amount of influence of the intensity of the hot air jet.
Název v anglickém jazyce
The effect of the window temperature on the thermal comfort in a room heated by a floor convector
Popis výsledku anglicky
The objective of this paper is the prediction of the surface temperature at a window with a prescribed heat flux, and how it affect the thermal comfort conditions in the space. The negative heat flux here represents the heat loss through a window. The temperature distribution at the window surface is a result of the interaction between a hot air jet and the cooled window surface. The temperature field at the window was determined by measurements using an infrared camera. The measurements were compared with CFD results. The k-epsilon RNG and k-omega turbulence modes were used for CFD simulation to classify the sensitivity of the temperature distribution on the turbulence model and the heat loss magnitude. Two directions and velocities of the hot air flux are compared. The calculation based on the k-omega turbulence model provided constant temperature distribution for wide range of heat fluxes. Results of the k-epsilon RNG model revealed the amount of influence of the intensity of the hot air jet.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01020231" target="_blank" >TA01020231: Aplikovaný výzkum zaměřený na zvýšení tepelné účinnosti výměníků tepla a provozní ověření v souvislosti s obnovitelnými zdroji energie.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate
ISBN
978-1-63439-731-5
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
494-502
Název nakladatele
International Society of Indoor Air Quality and Climate
Místo vydání
Hong Kong
Místo konání akce
Hong Kong
Datum konání akce
—
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—