Automatic parameter estimation in the model of underground buffer and rock heater test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F12%3A%230002821" target="_blank" >RIV/46747885:24220/12:#0002821 - isvavai.cz</a>
Výsledek na webu
<a href="http://bookshop.europa.eu/en/impact-of-thermo-hydro-mechanical-chemical-thmc-processes-on-the-safety-of-underground-radioactive-waste-repositories-pbKINA25527/" target="_blank" >http://bookshop.europa.eu/en/impact-of-thermo-hydro-mechanical-chemical-thmc-processes-on-the-safety-of-underground-radioactive-waste-repositories-pbKINA25527/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automatic parameter estimation in the model of underground buffer and rock heater test
Popis výsledku v původním jazyce
We present an example of using an optimization algorithm for the automatic estimation of material parameters, as an extension of common back-analyses of laboratory and in-situ experiments. The data used are from ?buffer/container experiment? in Canadianunderground laboratory. We use our own coupled heat and moisture transport model (ISERIT code) and the free parameters calibration program UCODE from the US Geological Survey. The optimization problem is solved for the simpler case of steady-state heat conduction. We present different cases of fixed and optimized parameters sets, some where the fit can be significantly improved with physically realistic parameters (small change from literature value) and some with non-convergent algorithm or physicallyunrealistic parameters in the optimum.
Název v anglickém jazyce
Automatic parameter estimation in the model of underground buffer and rock heater test
Popis výsledku anglicky
We present an example of using an optimization algorithm for the automatic estimation of material parameters, as an extension of common back-analyses of laboratory and in-situ experiments. The data used are from ?buffer/container experiment? in Canadianunderground laboratory. We use our own coupled heat and moisture transport model (ISERIT code) and the free parameters calibration program UCODE from the US Geological Survey. The optimization problem is solved for the simpler case of steady-state heat conduction. We present different cases of fixed and optimized parameters sets, some where the fit can be significantly improved with physically realistic parameters (small change from literature value) and some with non-convergent algorithm or physicallyunrealistic parameters in the optimum.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0554" target="_blank" >1M0554: Pokročilé sanační technologie a procesy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Impact of thermo-hydro-mechanical-chemical (THMC) processes on the safety of underground radioactive waste repositories
ISBN
978-92-79-26057-5
ISSN
1018-5593
e-ISSN
—
Počet stran výsledku
5
Strana od-do
281-285
Název nakladatele
Publications Office of the European Union
Místo vydání
Luxembourg
Místo konání akce
Luxembourg
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—