Indirect torque measurement using industrial vector control frequency converter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F16%3A00000290" target="_blank" >RIV/46747885:24220/16:00000290 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/CarpathianCC.2016.7501065" target="_blank" >http://dx.doi.org/10.1109/CarpathianCC.2016.7501065</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CarpathianCC.2016.7501065" target="_blank" >10.1109/CarpathianCC.2016.7501065</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Indirect torque measurement using industrial vector control frequency converter
Popis výsledku v původním jazyce
This article deals with accuracy of indirect torque measurement of converter-fed induction motors. The measurement was held on both mid-(7,5 kW) and low-power (0,5 kW) motors supplied by Siemens SINAMICS G120 frequency converters. The vector control method was used, the effects of speed sensor presence or absence were evaluated. Also the motor temperature influence was taken into account and the proper converter commissioning and tuning were tested. The load torque was produced by dynamometer test bench with gauge strain measurement of force (torque) and the whole working area of tested drives was used. The evaluation of results shows that the relative accuracy of torque value provided by a converter is acceptable for particular industrial applications and allows to reduce expenses for direct torque measurement device
Název v anglickém jazyce
Indirect torque measurement using industrial vector control frequency converter
Popis výsledku anglicky
This article deals with accuracy of indirect torque measurement of converter-fed induction motors. The measurement was held on both mid-(7,5 kW) and low-power (0,5 kW) motors supplied by Siemens SINAMICS G120 frequency converters. The vector control method was used, the effects of speed sensor presence or absence were evaluated. Also the motor temperature influence was taken into account and the proper converter commissioning and tuning were tested. The load torque was produced by dynamometer test bench with gauge strain measurement of force (torque) and the whole working area of tested drives was used. The evaluation of results shows that the relative accuracy of torque value provided by a converter is acceptable for particular industrial applications and allows to reduce expenses for direct torque measurement device
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2016 17th International Carpathian Control Conference, ICCC 2016
ISBN
9781467386067
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
""
Název nakladatele
—
Místo vydání
—
Místo konání akce
Tatranska Lomnica; Slovakia
Datum konání akce
1. 1. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—