On the accuracy of indirect torque measurement using frequency converter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F17%3A00004874" target="_blank" >RIV/46747885:24220/17:00004874 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7970366/" target="_blank" >http://ieeexplore.ieee.org/document/7970366/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CarpathianCC.2017.7970366" target="_blank" >10.1109/CarpathianCC.2017.7970366</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the accuracy of indirect torque measurement using frequency converter
Popis výsledku v původním jazyce
The article presents evaluation of indirect torque measurement accuracy of converter-fed induction motors. The low-power (5.5 kW) motor supplied by Siemens SINAMICS S120 frequency converters was used to perform the measurement. The converter was set up to vector control method, also the effects of speed sensor presence or absence were compared. The dynamometer test bench with gauge strain measurement of force (torque) to produce the load torque was used. It allows us to evaluate the whole working area of tested drive. The results show that the relative accuracy of torque value is acceptable for specific industrial applications and therefore it allows to cut down expenses for direct torque measurement device. The results presented in the article enlarges our measurement database focused on industrial frequency converter performance.
Název v anglickém jazyce
On the accuracy of indirect torque measurement using frequency converter
Popis výsledku anglicky
The article presents evaluation of indirect torque measurement accuracy of converter-fed induction motors. The low-power (5.5 kW) motor supplied by Siemens SINAMICS S120 frequency converters was used to perform the measurement. The converter was set up to vector control method, also the effects of speed sensor presence or absence were compared. The dynamometer test bench with gauge strain measurement of force (torque) to produce the load torque was used. It allows us to evaluate the whole working area of tested drive. The results show that the relative accuracy of torque value is acceptable for specific industrial applications and therefore it allows to cut down expenses for direct torque measurement device. The results presented in the article enlarges our measurement database focused on industrial frequency converter performance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2017 18th International Carpathian Control Conference, ICCC 2017
ISBN
978-150904862-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
28-33
Název nakladatele
Institute of Electrical and Electronics Engineers Inc.
Místo vydání
—
Místo konání akce
Palace HotelSinaia; Romania
Datum konání akce
1. 1. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—