A-Posteriori Synchronization of Power Quality Data in Smart Grids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F21%3A00009146" target="_blank" >RIV/46747885:24220/21:00009146 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9468829" target="_blank" >https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9468829</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ECMSM51310.2021.9468829" target="_blank" >10.1109/ECMSM51310.2021.9468829</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A-Posteriori Synchronization of Power Quality Data in Smart Grids
Popis výsledku v původním jazyce
This paper is concerned with synchronizing smart meter data in post-processing. A-posteriori synchronization is necessary in cases where real time online synchronization failed or was unavailable. In the paper, a simple method to synchronize power quality data series from multiple meters is proposed. The method analyses similarities in voltage data and estimates the lags between the meters. In order to obtain a single data series representing the most relevant phenomena that happen at the location of the smart meter, Singular Value Decomposition is used. It helps to decrease the dimensionality of the smart meter data to one. To synchronize the time of two or more metering devices the correlation between data series were calculated. Distance between zero and the maximum absolute peak of the cross-correlation is taken as a lag. For signals containing transients and dips, accuracy may be increased by correlating the first order difference of the signals. The output of the proposed algorithm is the value of signals‘ time lags. The accuracy of the algorithm is limited by the aggregation level of data under examination.
Název v anglickém jazyce
A-Posteriori Synchronization of Power Quality Data in Smart Grids
Popis výsledku anglicky
This paper is concerned with synchronizing smart meter data in post-processing. A-posteriori synchronization is necessary in cases where real time online synchronization failed or was unavailable. In the paper, a simple method to synchronize power quality data series from multiple meters is proposed. The method analyses similarities in voltage data and estimates the lags between the meters. In order to obtain a single data series representing the most relevant phenomena that happen at the location of the smart meter, Singular Value Decomposition is used. It helps to decrease the dimensionality of the smart meter data to one. To synchronize the time of two or more metering devices the correlation between data series were calculated. Distance between zero and the maximum absolute peak of the cross-correlation is taken as a lag. For signals containing transients and dips, accuracy may be increased by correlating the first order difference of the signals. The output of the proposed algorithm is the value of signals‘ time lags. The accuracy of the algorithm is limited by the aggregation level of data under examination.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2021 IEEE International Workshop of Electronics, Control, Measurement, Signals and their Application to Mechatronics, ECMSM 2021
ISBN
978-153861757-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
—
Místo konání akce
Liberec
Datum konání akce
1. 1. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—