The influence of measured spectral band-pass width on calculation of colorimetric parameters of color objects
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F11%3A%230001001" target="_blank" >RIV/46747885:24410/11:#0001001 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of measured spectral band-pass width on calculation of colorimetric parameters of color objects
Popis výsledku v původním jazyce
Tristimulus values XYZ are fundamental to colorimetry and are used in the industry for such things as color specification, color matching and shade sorting. The CIE proposes methods on how XYZ are to be calculated. In this article methods for computing optimum weighing tables for any illuminant and observer combination are compared. A comprehensive set of 1-nm reflectance functions based on BCRA CCSII ceramic tile set was used for evaluation calculated colorimetric parameters. We have investigated the colorimetric differences caused by using the different methods for computing optimum weighing tables are important in case of fluorescent light sources. As further result we found that by using 1nm tables is possible to obtain high precision of tristimulus values calculation based on cubic spline interpolation of 10 nm reflectance data.
Název v anglickém jazyce
The influence of measured spectral band-pass width on calculation of colorimetric parameters of color objects
Popis výsledku anglicky
Tristimulus values XYZ are fundamental to colorimetry and are used in the industry for such things as color specification, color matching and shade sorting. The CIE proposes methods on how XYZ are to be calculated. In this article methods for computing optimum weighing tables for any illuminant and observer combination are compared. A comprehensive set of 1-nm reflectance functions based on BCRA CCSII ceramic tile set was used for evaluation calculated colorimetric parameters. We have investigated the colorimetric differences caused by using the different methods for computing optimum weighing tables are important in case of fluorescent light sources. As further result we found that by using 1nm tables is possible to obtain high precision of tristimulus values calculation based on cubic spline interpolation of 10 nm reflectance data.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0553" target="_blank" >1M0553: Výzkumné centrum TEXTIL II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Světlo 2011 - LIGHT 2011
ISBN
978-80-248-2480-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
113-116
Název nakladatele
VŠB-TU Ostrava
Místo vydání
Ostrava. Czech Republic
Místo konání akce
Praha
Datum konání akce
21. 9. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—