Dynamic heat flux measurement for advanced insulation materials
Popis výsledku v původním jazyce
This research elaborates determination of thermal characteristics e.g. thermal conductivity, resistance, convectionand clo value of advanced thermal insulation materials using standing thermal manikin and a newly designed instrument in a controlled climatic chamber. A multi-segment thermal manikin with the thermal comfort regulation mode and a newlydevised instrument was used to measure the forced convection through aerogel treated nonwoven fabrics and needle punched struto nonwoven fabric samples. With the newly designed instrument, the temperatures between the hotplate & fabric and on the surface of the fabric was measured keeping the temperature of climatic chamber constant. The convective heat transfer coefficient, conductivity and resistance was calculated accordingly and compared among the samples. In experiments with the thermal manikin, the temperatures and heat flux were measured for further calculation of resistance and clo values. The aerogel treated nonwoven fabrics showed higher resistance as compared to needle punched struto nonwoven fabrics. The results were analyzed and were statistically compared.
Název v anglickém jazyce
Dynamic heat flux measurement for advanced insulation materials
Popis výsledku anglicky
This research elaborates determination of thermal characteristics e.g. thermal conductivity, resistance, convectionand clo value of advanced thermal insulation materials using standing thermal manikin and a newly designed instrument in a controlled climatic chamber. A multi-segment thermal manikin with the thermal comfort regulation mode and a newlydevised instrument was used to measure the forced convection through aerogel treated nonwoven fabrics and needle punched struto nonwoven fabric samples. With the newly designed instrument, the temperatures between the hotplate & fabric and on the surface of the fabric was measured keeping the temperature of climatic chamber constant. The convective heat transfer coefficient, conductivity and resistance was calculated accordingly and compared among the samples. In experiments with the thermal manikin, the temperatures and heat flux were measured for further calculation of resistance and clo values. The aerogel treated nonwoven fabrics showed higher resistance as compared to needle punched struto nonwoven fabrics. The results were analyzed and were statistically compared.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fibers and Polymers
ISSN
1229-9197
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
KP - Korejská lidově demokratická republika
Počet stran výsledku
7
Strana od-do
925-931
Kód UT WoS článku
000378972800015
EID výsledku v databázi Scopus
2-s2.0-84983087332