Graft orientation influences meshing ratio
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F18%3A00005946" target="_blank" >RIV/46747885:24410/18:00005946 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064211:_____/18:W0000108
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.burns.2018.05.001" target="_blank" >http://dx.doi.org/10.1016/j.burns.2018.05.001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.burns.2018.05.001" target="_blank" >10.1016/j.burns.2018.05.001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Graft orientation influences meshing ratio
Popis výsledku v původním jazyce
The technique of meshed skin grafting is known since 1960s. It was shown that there is a difference between the declared and real expansion ratio of the skin meshed graft. We hypothesize that the orientation of the Langer's lines in a split thickness skin graft is a key parameter in the resulting expansion ratio. The skin graft meshing process was analyzed in two steps. In the first step, ex vivo uniaxial tests of human skin were performed. This served as an input for the constitutive model used for numerical simulations. In the second step, finite element analyses were performed so that stress distributions and expansion ratios could be determined. It was shown that peaks of true stress tended to be concentrated around the vertex of the mesh pattern region for all cases. The declared expansion was impossible to obtain for all expansion ratios having the meshing incision perpendicular to the Langer's lines. The highest difference between declared and real expansion ratio reaches 37%. With regard to literature dealing with expansion of skin grafts by meshing, a high scatter amongst data results is observed. This finding was also explained by our research, demonstrating the significance of Langer's lines and their relative orientation to the direction of meshing.
Název v anglickém jazyce
Graft orientation influences meshing ratio
Popis výsledku anglicky
The technique of meshed skin grafting is known since 1960s. It was shown that there is a difference between the declared and real expansion ratio of the skin meshed graft. We hypothesize that the orientation of the Langer's lines in a split thickness skin graft is a key parameter in the resulting expansion ratio. The skin graft meshing process was analyzed in two steps. In the first step, ex vivo uniaxial tests of human skin were performed. This served as an input for the constitutive model used for numerical simulations. In the second step, finite element analyses were performed so that stress distributions and expansion ratios could be determined. It was shown that peaks of true stress tended to be concentrated around the vertex of the mesh pattern region for all cases. The declared expansion was impossible to obtain for all expansion ratios having the meshing incision perpendicular to the Langer's lines. The highest difference between declared and real expansion ratio reaches 37%. With regard to literature dealing with expansion of skin grafts by meshing, a high scatter amongst data results is observed. This finding was also explained by our research, demonstrating the significance of Langer's lines and their relative orientation to the direction of meshing.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10610 - Biophysics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Burns
ISSN
0305-4179
e-ISSN
—
Svazek periodika
44
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1439-1445
Kód UT WoS článku
000444542300007
EID výsledku v databázi Scopus
2-s2.0-85048543175