Guidelines for measuring thermal resistance on thermal Foot Manikin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F20%3A00007043" target="_blank" >RIV/46747885:24410/20:00007043 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2214785319337514?vi" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2214785319337514?vi</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.matpr.2019.11.068" target="_blank" >10.1016/j.matpr.2019.11.068</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Guidelines for measuring thermal resistance on thermal Foot Manikin
Popis výsledku v původním jazyce
This study aims to optimize the factors affecting thermal resistance (Rct) test on Thermal Foot Manikin (TFM). There are two types of testing on Thermal Manikin (nude and clothed manikin). Initial thermal resistance (Rct0) is measured on both nude and clothed TFM. Clothed TFM is using mercerized cotton socks. Thermal resistance (Rct) is evaluated for four types of woven compression bandages (WCBs). All bandage types were applied at extension ranges 10 to 80%, using both two- and three-layers bandaging. Moreover all samples were measured on three levels of ambient conditions (T: 20±2 °C, RH: 65±5%), (T: 22±2 °C, RH: 65±5%), (T: 20±2 °C, RH: 50±5%). The main factors affecting thermal resistance test are the temperature difference between ambient conditions and skin, yarns material, fabric structure (woven, knitted), thickness, weight per unit area, number of fabric and air layers. Obtained results of Rct0 and Rct confirmed that clothed TFM is more accurate due to more stabilization and less effect of air convection.
Název v anglickém jazyce
Guidelines for measuring thermal resistance on thermal Foot Manikin
Popis výsledku anglicky
This study aims to optimize the factors affecting thermal resistance (Rct) test on Thermal Foot Manikin (TFM). There are two types of testing on Thermal Manikin (nude and clothed manikin). Initial thermal resistance (Rct0) is measured on both nude and clothed TFM. Clothed TFM is using mercerized cotton socks. Thermal resistance (Rct) is evaluated for four types of woven compression bandages (WCBs). All bandage types were applied at extension ranges 10 to 80%, using both two- and three-layers bandaging. Moreover all samples were measured on three levels of ambient conditions (T: 20±2 °C, RH: 65±5%), (T: 22±2 °C, RH: 65±5%), (T: 20±2 °C, RH: 50±5%). The main factors affecting thermal resistance test are the temperature difference between ambient conditions and skin, yarns material, fabric structure (woven, knitted), thickness, weight per unit area, number of fabric and air layers. Obtained results of Rct0 and Rct confirmed that clothed TFM is more accurate due to more stabilization and less effect of air convection.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20503 - Textiles; including synthetic dyes, colours, fibres (nanoscale materials to be 2.10; biomaterials to be 2.9)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Materials Today: Proceedings Vol.31, Supplement 2
ISBN
—
ISSN
2214-7853
e-ISSN
—
Počet stran výsledku
4
Strana od-do
232-235
Název nakladatele
Elsevier, Ltd.
Místo vydání
—
Místo konání akce
Porto, Portugal
Datum konání akce
1. 1. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000581129200009