How Different Cleaning Procedures Affect Reliability of Conductive Joints on E-Textiles?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F24%3A00013014" target="_blank" >RIV/46747885:24410/24:00013014 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/ISSE61612.2024.10603669" target="_blank" >https://doi.org/10.1109/ISSE61612.2024.10603669</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISSE61612.2024.10603669" target="_blank" >10.1109/ISSE61612.2024.10603669</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
How Different Cleaning Procedures Affect Reliability of Conductive Joints on E-Textiles?
Popis výsledku v původním jazyce
This article deals with the influence of different cleaning procedures (washing 40 degrees C, 60 degrees C, 92 degrees C, dry cleaning, wet cleaning) on reliability of conductive joints onto conductive stretchable textile ribbons. In the experiment, the two different conductive connection techniques (low temperature soldering, non-conductive adhesive glueing) are used. The results show that low temperature washing (40 degrees C) or wet cleaning can be used for cleaning of textiles with ribbons with acceptable degradation of joints electrical resistance. The results also show that higher temperature washing and dry cleaning significantly degrade joints electrical resistance and also the ribbon itself.
Název v anglickém jazyce
How Different Cleaning Procedures Affect Reliability of Conductive Joints on E-Textiles?
Popis výsledku anglicky
This article deals with the influence of different cleaning procedures (washing 40 degrees C, 60 degrees C, 92 degrees C, dry cleaning, wet cleaning) on reliability of conductive joints onto conductive stretchable textile ribbons. In the experiment, the two different conductive connection techniques (low temperature soldering, non-conductive adhesive glueing) are used. The results show that low temperature washing (40 degrees C) or wet cleaning can be used for cleaning of textiles with ribbons with acceptable degradation of joints electrical resistance. The results also show that higher temperature washing and dry cleaning significantly degrade joints electrical resistance and also the ribbon itself.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
<a href="/cs/project/FW03010095" target="_blank" >FW03010095: MultiTex - Pokročilé smart textilie s multifunkčními účinky pro zkvalitnění profesních a funkčních oděvů v rizikovém prostředí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 47TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, ISSE 2024
ISBN
979-8-3503-8548-9
ISSN
2161-2536
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
IEEE
Místo vydání
NEW YORK
Místo konání akce
Praha
Datum konání akce
1. 1. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001283808200021