The Water Vapour Resistance Dynamic Measurement Of Natural And Synthetic Fibre
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F24%3A00013338" target="_blank" >RIV/46747885:24410/24:00013338 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1108/ijcst-01-2024-0012" target="_blank" >https://doi.org/10.1108/ijcst-01-2024-0012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1108/IJCST-01-2024-0012" target="_blank" >10.1108/IJCST-01-2024-0012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Water Vapour Resistance Dynamic Measurement Of Natural And Synthetic Fibre
Popis výsledku v původním jazyce
PurposeThe paper aims to investigate the dynamic measurement of the water vapour resistance. The water vapour diffusion kinetics depends on the fibre‘s material. So, water vapour resistance measurement times till the equilibrium steady state can vary in the case of natural fibres compared to synthetic fibres. Devices for determining water vapour resistance according to the ISO 11092 standard allow static values to be measured.Design/methodology/approachIn this study to investigate the dynamic of the water vapour resistance, a new parameter named „holding period” was introduced and defined as the time from sample placement on the measuring head until the measuring process begins. The holding period was varied as 0, 30, 60, 90, 120, 180, 240 and 300 s. Wool and cotton knitted fabrics were tested as natural fibres and compared to 100% polyester and 90% polyester/10% elastane as synthetic fibres. Measurements were conducted under both air velocities of 1 and 2 m/s. The experimental test data were statistically analysed based on ANOVA and four-in-one residual plots.FindingsStatistical analysis of experimental tests shows that the holding period affects water vapour resistance in both air velocities of 1 and 2 m/s and on the measured values in the case of hydrophilic fibres.Research limitations/implicationsThe study of the dynamic relative water vapour permeability of natural and synthetic is an important area of interest for future research.Practical implicationsIt is recommended to hold the samples on the top of the head measurement before starting the test.Originality/valueFollowing the ISO 11092 standard, the static values of the water vapour resistance were measured without considering the dynamic behaviour of the water vapour diffusion through the textile fabrics. This paper fulfils an experimental dynamic measurement of the water vapour resistance.
Název v anglickém jazyce
The Water Vapour Resistance Dynamic Measurement Of Natural And Synthetic Fibre
Popis výsledku anglicky
PurposeThe paper aims to investigate the dynamic measurement of the water vapour resistance. The water vapour diffusion kinetics depends on the fibre‘s material. So, water vapour resistance measurement times till the equilibrium steady state can vary in the case of natural fibres compared to synthetic fibres. Devices for determining water vapour resistance according to the ISO 11092 standard allow static values to be measured.Design/methodology/approachIn this study to investigate the dynamic of the water vapour resistance, a new parameter named „holding period” was introduced and defined as the time from sample placement on the measuring head until the measuring process begins. The holding period was varied as 0, 30, 60, 90, 120, 180, 240 and 300 s. Wool and cotton knitted fabrics were tested as natural fibres and compared to 100% polyester and 90% polyester/10% elastane as synthetic fibres. Measurements were conducted under both air velocities of 1 and 2 m/s. The experimental test data were statistically analysed based on ANOVA and four-in-one residual plots.FindingsStatistical analysis of experimental tests shows that the holding period affects water vapour resistance in both air velocities of 1 and 2 m/s and on the measured values in the case of hydrophilic fibres.Research limitations/implicationsThe study of the dynamic relative water vapour permeability of natural and synthetic is an important area of interest for future research.Practical implicationsIt is recommended to hold the samples on the top of the head measurement before starting the test.Originality/valueFollowing the ISO 11092 standard, the static values of the water vapour resistance were measured without considering the dynamic behaviour of the water vapour diffusion through the textile fabrics. This paper fulfils an experimental dynamic measurement of the water vapour resistance.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20503 - Textiles; including synthetic dyes, colours, fibres (nanoscale materials to be 2.10; biomaterials to be 2.9)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY
ISSN
0955-6222
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
1094-1105
Kód UT WoS článku
001288481200001
EID výsledku v databázi Scopus
2-s2.0-85201010060