Imperfections of gravimetric methods for the measurement of water vapour permeability of fabrics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F10%3A%230000774" target="_blank" >RIV/46747885:24410/10:#0000774 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Imperfections of gravimetric methods for the measurement of water vapour permeability of fabrics
Popis výsledku v původním jazyce
In the paper, thermomechanical analysis of some gravimetric methods for testing the water vapour permeability of fabrics is outlined, with the objective to determine selected factors, which may cause the measurement imperfection. It was confirmed, that the changing space between the water level and a sample, unsteady velocity of the air flow along the sample and namely varying parameters of the temperature and humidity of the air (water vapour) on both sides of the sample can substantially affect the measurement precision. From the conclusions follows, that simple conversion between the data obtained from gravimetric methods and the evaporation resisistance Ret according the ISO 11092 is not possible, without knowledge of certain parameter of the testing device.
Název v anglickém jazyce
Imperfections of gravimetric methods for the measurement of water vapour permeability of fabrics
Popis výsledku anglicky
In the paper, thermomechanical analysis of some gravimetric methods for testing the water vapour permeability of fabrics is outlined, with the objective to determine selected factors, which may cause the measurement imperfection. It was confirmed, that the changing space between the water level and a sample, unsteady velocity of the air flow along the sample and namely varying parameters of the temperature and humidity of the air (water vapour) on both sides of the sample can substantially affect the measurement precision. From the conclusions follows, that simple conversion between the data obtained from gravimetric methods and the evaporation resisistance Ret according the ISO 11092 is not possible, without knowledge of certain parameter of the testing device.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
4th Aachen-Dresden Conference
ISBN
978-4-901381-32-1
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
—
Místo vydání
Dresden, Germany
Místo konání akce
Dresden, Germany
Datum konání akce
25. 11. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—