Flow field velocity measurement of liquid interaction with rigid and flexible wall
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F18%3A00005867" target="_blank" >RIV/46747885:24620/18:00005867 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow field velocity measurement of liquid interaction with rigid and flexible wall
Popis výsledku v původním jazyce
The motivation of this research was to determine the flow interactions on the pulsation and to express the influence on the flow character in the rigid and flexible tube. The character of Newtonian liquid was measured with the Particle Image Velocimetry method (PIV). Here, we used glass tube and Tygon tube for our comparison. We build the circuit equipped with membrane pump for generating pulsatile flow. The results were analysed over the pulse period sampled in 10 time steps. The fluid flow varied from Re 560 to Re 8800. The velocity profiles uncovered backward revers flows closed to the wall. These structures are prevailing close to flexible wall. The effect of interaction between pulsatile liquid flow and flexible wall was experimentally proved.
Název v anglickém jazyce
Flow field velocity measurement of liquid interaction with rigid and flexible wall
Popis výsledku anglicky
The motivation of this research was to determine the flow interactions on the pulsation and to express the influence on the flow character in the rigid and flexible tube. The character of Newtonian liquid was measured with the Particle Image Velocimetry method (PIV). Here, we used glass tube and Tygon tube for our comparison. We build the circuit equipped with membrane pump for generating pulsatile flow. The results were analysed over the pulse period sampled in 10 time steps. The fluid flow varied from Re 560 to Re 8800. The velocity profiles uncovered backward revers flows closed to the wall. These structures are prevailing close to flexible wall. The effect of interaction between pulsatile liquid flow and flexible wall was experimentally proved.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů