Correlation of Microstructure Development of Cast CB2 Steel after Lomg-Term Creep Tests with Electrochemical Characteristics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F47718684%3A_____%2F12%3A%230000496" target="_blank" >RIV/47718684:_____/12:#0000496 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correlation of Microstructure Development of Cast CB2 Steel after Lomg-Term Creep Tests with Electrochemical Characteristics
Popis výsledku v původním jazyce
Specimens for long-term creep tests were taken from two different positions in the pilot valve made of cast CB2 steel, which was developed within the COST programs. Creep testing was carried out at 650°C and a stress range from 50 MPa to 120 MPa. The longest time to rupture was 82,649 hours, however some tests are still running. Ruptured samples underwent fractographic and microstructural analyses and electrochemical measurements. Quantitative evaluation of substructure was performed using SEM and TEM of extraction carbon replicas and thin foils. Microstructure of the virgin material and crept specimens were compared and correlated with electrochemical characteristics measured on the base of the potentiokinetic polarization curves with aim to test a possibility of access of material degradation using electrochemical measurement. Precipitation processes taking place during creep exposures resulted in changes of polarization curves. Extra peak of the current density was detected in the r
Název v anglickém jazyce
Correlation of Microstructure Development of Cast CB2 Steel after Lomg-Term Creep Tests with Electrochemical Characteristics
Popis výsledku anglicky
Specimens for long-term creep tests were taken from two different positions in the pilot valve made of cast CB2 steel, which was developed within the COST programs. Creep testing was carried out at 650°C and a stress range from 50 MPa to 120 MPa. The longest time to rupture was 82,649 hours, however some tests are still running. Ruptured samples underwent fractographic and microstructural analyses and electrochemical measurements. Quantitative evaluation of substructure was performed using SEM and TEM of extraction carbon replicas and thin foils. Microstructure of the virgin material and crept specimens were compared and correlated with electrochemical characteristics measured on the base of the potentiokinetic polarization curves with aim to test a possibility of access of material degradation using electrochemical measurement. Precipitation processes taking place during creep exposures resulted in changes of polarization curves. Extra peak of the current density was detected in the r
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2nd International Conference COMAT 2012
ISBN
978-80-87294-34-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
6
Název nakladatele
Tanger Ltd.
Místo vydání
Ostrava
Místo konání akce
Plzeň
Datum konání akce
21. 11. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—