Vše

Co hledáte?

Vše
Projekty
Výsledky výzkumu
Subjekty

Rychlé hledání

  • Projekty podpořené TA ČR
  • Významné projekty
  • Projekty s nejvyšší státní podporou
  • Aktuálně běžící projekty

Chytré vyhledávání

  • Takto najdu konkrétní +slovo
  • Takto z výsledků -slovo zcela vynechám
  • “Takto můžu najít celou frázi”

Computer analysis and evaluation of ultrasound Bimages universally usable due to principle of BMODE and its displaying in grayscale

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F47813059%3A19240%2F15%3A%230005544" target="_blank" >RIV/47813059:19240/15:#0005544 - isvavai.cz</a>

  • Výsledek na webu

    <a href="http://dx.doi.org/10.1109/ICCSPA.2015.7081270" target="_blank" >http://dx.doi.org/10.1109/ICCSPA.2015.7081270</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/ICCSPA.2015.7081270" target="_blank" >10.1109/ICCSPA.2015.7081270</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Computer analysis and evaluation of ultrasound Bimages universally usable due to principle of BMODE and its displaying in grayscale

  • Popis výsledku v původním jazyce

    We developed an algorithm and simultaneously a computer program to analysis and evaluation of ultrasound Bimages. Ultrasound B-imaging is one of mostly used displaying method in radiology. Our developed method and program use of the principle of B-imaging and displaying in grayscale according to pulse-echo approach principle. The program is focused on measurement echogenic area inside defined ROI. So, we measure level of echogenicity for examined tissue. It is based on binary thresholding due to grayscale displaying. We observe how echogenic area is changed according to threshold. Results were verified by an experienced sonographer and also by independent observers. We also observed average correlation between different ultrasound machines (r > 0.82) and between observers (r > 0.85, inter-kappa > 0.83, intra-kappa > 0.9). Up to now we tested the program for substantia nigra echogenicity to Parkinson's Disease diagnosis, raphe nucleus echogenicity and currently we examine atheroscleroti

  • Název v anglickém jazyce

    Computer analysis and evaluation of ultrasound Bimages universally usable due to principle of BMODE and its displaying in grayscale

  • Popis výsledku anglicky

    We developed an algorithm and simultaneously a computer program to analysis and evaluation of ultrasound Bimages. Ultrasound B-imaging is one of mostly used displaying method in radiology. Our developed method and program use of the principle of B-imaging and displaying in grayscale according to pulse-echo approach principle. The program is focused on measurement echogenic area inside defined ROI. So, we measure level of echogenicity for examined tissue. It is based on binary thresholding due to grayscale displaying. We observe how echogenic area is changed according to threshold. Results were verified by an experienced sonographer and also by independent observers. We also observed average correlation between different ultrasound machines (r > 0.82) and between observers (r > 0.85, inter-kappa > 0.83, intra-kappa > 0.9). Up to now we tested the program for substantia nigra echogenicity to Parkinson's Disease diagnosis, raphe nucleus echogenicity and currently we examine atheroscleroti

Klasifikace

  • Druh

    D - Stať ve sborníku

  • CEP obor

    IN - Informatika

  • OECD FORD obor

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/ED1.1.00%2F02.0070" target="_blank" >ED1.1.00/02.0070: Centrum excelence IT4Innovations</a><br>

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Ostatní

  • Rok uplatnění

    2015

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název statě ve sborníku

    Communications, Signal Processing, and their Applications (ICCSPA), 2015 International Conference on Communications, Signal Processing, and their Applications (ICCSPA)

  • ISBN

    9781479965335

  • ISSN

  • e-ISSN

  • Počet stran výsledku

    6

  • Strana od-do

  • Název nakladatele

    IEEE

  • Místo vydání

  • Místo konání akce

    Sharjah

  • Datum konání akce

    1. 1. 2015

  • Typ akce podle státní příslušnosti

    WRD - Celosvětová akce

  • Kód UT WoS článku