Popis výsledku v původním jazyce
The paper describes the behavior of diagnostic parameter tan d of cured mica-composites in dependence on curing temperature. The material studied consists of two different three-layer mica composites, which are normally used for the manufacture of main wall insulation in electrical rotating machines. The specimens were cured over six different temperatures 130-180 °C. The main diagnostic parameter tan d was measured online during the curing (curing characteristics) and after curing process. The temperature dependence of tan d was measured after the isothermal curing. The magnitude tan d give very good information capability about materials during their curing and allows to determine the optimal curing temperature. The tan d is also able to determine possible undercuring of the insulation, which occurs at lower curing temperatures.
Název v anglickém jazyce
The Electric Properties of Cured Mica-Glass Composites
Popis výsledku anglicky
The paper describes the behavior of diagnostic parameter tan d of cured mica-composites in dependence on curing temperature. The material studied consists of two different three-layer mica composites, which are normally used for the manufacture of main wall insulation in electrical rotating machines. The specimens were cured over six different temperatures 130-180 °C. The main diagnostic parameter tan d was measured online during the curing (curing characteristics) and after curing process. The temperature dependence of tan d was measured after the isothermal curing. The magnitude tan d give very good information capability about materials during their curing and allows to determine the optimal curing temperature. The tan d is also able to determine possible undercuring of the insulation, which occurs at lower curing temperatures.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Zeszyty problemowe - Maszyny elektryczne
ISSN
0239-3646
e-ISSN
—
Svazek periodika
2006
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
5
Strana od-do
147
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—