Aspects of pd-measurements in h.v.-testing using static frequency converters
Popis výsledku v původním jazyce
In h.v. testing more and more static frequency converters (SFC) will be used as an appropriate alternative to the conventional and expensive motor- generator- sets, e.g. for testing of power transformer at higher frequencies. One of the most problems herein is the existence of relatively large electromagnetic disturbances, caused by the switching part of SFC, In the paper will be described, that for overcoming these problems two possibilities should beimpossible. In the paper will be described, that forovercoming these problems two possibilities should beapplied. At one for arranging of the SFC in the testing area all possible EMC- measures should be provided, as shown in an exemplary h.v.- testing circuit.. On the other hand the using of special measures in the pdmeasurement-is necessary. With the described measures a pd- sensitivity of less than 30 pC for a prototype h.v.- system could be reached.
Název v anglickém jazyce
Aspects of pd-measurements in h.v.-testing using static frequency converters
Popis výsledku anglicky
In h.v. testing more and more static frequency converters (SFC) will be used as an appropriate alternative to the conventional and expensive motor- generator- sets, e.g. for testing of power transformer at higher frequencies. One of the most problems herein is the existence of relatively large electromagnetic disturbances, caused by the switching part of SFC, In the paper will be described, that for overcoming these problems two possibilities should beimpossible. In the paper will be described, that forovercoming these problems two possibilities should beapplied. At one for arranging of the SFC in the testing area all possible EMC- measures should be provided, as shown in an exemplary h.v.- testing circuit.. On the other hand the using of special measures in the pdmeasurement-is necessary. With the described measures a pd- sensitivity of less than 30 pC for a prototype h.v.- system could be reached.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Elektroenergetika 2007
ISBN
978-80-8073-844-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
293-296
Název nakladatele
Technical University
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
1. 1. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—