Elektrické vlastnosti kombinované izolace
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F08%3A00500445" target="_blank" >RIV/49777513:23220/08:00500445 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrical properties propagation of exposed combined insulation
Popis výsledku v původním jazyce
Power transformers are inconsiderable group of the electrical appliances with two components insulation system. One of the components - liquid insulating medium plays two roles- insulating and cooling. It can be mineral as well as synthetic based liquid.Second component is an organic based solid insulation usually of cellulose character. It is possible to follow two approaches for the materials evaluation. One of the ways is direct observation of the structure changes; structural approach. Second is response observation of the deteriorated materials. This is provided due to the electrical parameters measurement. Insulation materials are subjected to fastened aging process. In this case the fastened aging is provided by increasing the temperature to 90°C for the times 50 to 3000 hours. Measured were time dependencies of the dissipation factor, polarization index, permittivity and insulation resistance.
Název v anglickém jazyce
Electrical properties propagation of exposed combined insulation
Popis výsledku anglicky
Power transformers are inconsiderable group of the electrical appliances with two components insulation system. One of the components - liquid insulating medium plays two roles- insulating and cooling. It can be mineral as well as synthetic based liquid.Second component is an organic based solid insulation usually of cellulose character. It is possible to follow two approaches for the materials evaluation. One of the ways is direct observation of the structure changes; structural approach. Second is response observation of the deteriorated materials. This is provided due to the electrical parameters measurement. Insulation materials are subjected to fastened aging process. In this case the fastened aging is provided by increasing the temperature to 90°C for the times 50 to 3000 hours. Measured were time dependencies of the dissipation factor, polarization index, permittivity and insulation resistance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
16th IEEE International Conference on Dielectric Liquids ICDL 2008
ISBN
978-1-4244-1586-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Poitiers
Datum konání akce
3. 7. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce