Control of Induction Machine Drive for Multisystem Locomotive: Design Considerations Regarding Problems of Conductive Currents Affecting Railway Safety System
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F09%3A00501975" target="_blank" >RIV/49777513:23220/09:00501975 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Control of Induction Machine Drive for Multisystem Locomotive: Design Considerations Regarding Problems of Conductive Currents Affecting Railway Safety System
Popis výsledku v původním jazyce
This paper describes design of a new control and PWM algorithms for a main drive of a multisystem locomotive with special focus on investigation into the trolley-wire current which could disturb railway safety systems. Designed control is based on rotorflux oriented vector control in Cartesian coordinates which is unusually operated due to specific PWM in whole speed range. We employ a synchronous PWM based on a harmonic elimination strategy which is optimized regarding mitigation of the drive interaction with railway safety system. Verification of proper function of proposed control including trolley-wire current analysis has been done on designed laboratory prototype of locomotive drive. Major results of extensive experimental study made on this prototype are introduced in this contribution.
Název v anglickém jazyce
Control of Induction Machine Drive for Multisystem Locomotive: Design Considerations Regarding Problems of Conductive Currents Affecting Railway Safety System
Popis výsledku anglicky
This paper describes design of a new control and PWM algorithms for a main drive of a multisystem locomotive with special focus on investigation into the trolley-wire current which could disturb railway safety systems. Designed control is based on rotorflux oriented vector control in Cartesian coordinates which is unusually operated due to specific PWM in whole speed range. We employ a synchronous PWM based on a harmonic elimination strategy which is optimized regarding mitigation of the drive interaction with railway safety system. Verification of proper function of proposed control including trolley-wire current analysis has been done on designed laboratory prototype of locomotive drive. Major results of extensive experimental study made on this prototype are introduced in this contribution.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F1164" target="_blank" >GA102/09/1164: Interakce výkonových polovodičových měničů s okolím</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2009 13th European conference on power electronics and applications
ISBN
978-1-4244-4432-8
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
IEEE Service ctr
Místo vydání
Piscataway
Místo konání akce
Barcelona, Španělsko
Datum konání akce
10. 9. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—