Influence of electromagnetic interference on the analog part of hybrid pixel detectors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F11%3A43896774" target="_blank" >RIV/49777513:23220/11:43896774 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/11:00188271
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1748-0221/6/12/C12028" target="_blank" >http://dx.doi.org/10.1088/1748-0221/6/12/C12028</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/6/12/C12028" target="_blank" >10.1088/1748-0221/6/12/C12028</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of electromagnetic interference on the analog part of hybrid pixel detectors
Popis výsledku v původním jazyce
The analog signal from the sensor of hybrid semiconductor pixel detectors is prone to electro-magnetic interference. The study and diagnosis of induced and common electro-magnetic coupling between the analog part and digital part of these devices is required. The influence of electro-magnetic interference was tested on the setup with a pixel detector Timepix or Medipix and a FITPix read-out interface. Measurements were carried out of external as well as internal interference. We evaluated the influenceof both sources of electro-magnetic interference to the noise recorded by pixels. We measured the local spatial intensity distribution and frequency spectrum of the electro-magnetic field originating inside the readout chip during its own operation. In context of this test we exposed the detector chip to a locally generated artificial electro-magnetic field evaluating its sensitivity to induced interference. Consequently, the whole setup of the detector and read-out interface was exposed
Název v anglickém jazyce
Influence of electromagnetic interference on the analog part of hybrid pixel detectors
Popis výsledku anglicky
The analog signal from the sensor of hybrid semiconductor pixel detectors is prone to electro-magnetic interference. The study and diagnosis of induced and common electro-magnetic coupling between the analog part and digital part of these devices is required. The influence of electro-magnetic interference was tested on the setup with a pixel detector Timepix or Medipix and a FITPix read-out interface. Measurements were carried out of external as well as internal interference. We evaluated the influenceof both sources of electro-magnetic interference to the noise recorded by pixels. We measured the local spatial intensity distribution and frequency spectrum of the electro-magnetic field originating inside the readout chip during its own operation. In context of this test we exposed the detector chip to a locally generated artificial electro-magnetic field evaluating its sensitivity to induced interference. Consequently, the whole setup of the detector and read-out interface was exposed
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
Neuveden
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—