Inductive rotary probe for partial discharge diagnostics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F11%3A43913631" target="_blank" >RIV/49777513:23220/11:43913631 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inductive rotary probe for partial discharge diagnostics
Popis výsledku v původním jazyce
When the partial discharge within insulation system of generator stator occurs, there are several methods to detect the signal of such dangerous discharge. First the global method detecting discharge current impulse and second the method based on detecting of discharge emitted electro-magnetic energy. The indirect measuring of current discharge using inductive probe is described in this paper. This method uses inductive probe which output is analyzed by digital measuring oscilloscope technique and software specially developed to partial discharge detailed analysis. Instead of common global test there is necessary to use special localization method, as described above, for analyzing the ratio of partial discharge activity within particular stator slot of electrical rotating generator and its stator slots respectively. Method of inductive probe in differential setup is very useful to this diagnostics of rotating machines
Název v anglickém jazyce
Inductive rotary probe for partial discharge diagnostics
Popis výsledku anglicky
When the partial discharge within insulation system of generator stator occurs, there are several methods to detect the signal of such dangerous discharge. First the global method detecting discharge current impulse and second the method based on detecting of discharge emitted electro-magnetic energy. The indirect measuring of current discharge using inductive probe is described in this paper. This method uses inductive probe which output is analyzed by digital measuring oscilloscope technique and software specially developed to partial discharge detailed analysis. Instead of common global test there is necessary to use special localization method, as described above, for analyzing the ratio of partial discharge activity within particular stator slot of electrical rotating generator and its stator slots respectively. Method of inductive probe in differential setup is very useful to this diagnostics of rotating machines
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Annals of DAAAM for 2011 & Proceedings
ISBN
978-3-901509-83-4
ISSN
1726-9679
e-ISSN
—
Počet stran výsledku
2
Strana od-do
79-80
Název nakladatele
DAAAM International Vienna
Místo vydání
Vienna
Místo konání akce
Vídeň
Datum konání akce
23. 11. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—