Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F12%3A43915666" target="_blank" >RIV/49777513:23220/12:43915666 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination
Popis výsledku v původním jazyce
This paper describes a method that uses two cuffs to improve accuracy of blood pressure and hemodynamics estimation. A specially designed dual-cuff experimental system was used to acquire and process data from the two cuffs. The arm cuff provided cuff pressures and cuff arterial pulse waveforms. The arm cuff pulse pressure waveforms were used to compute mean arterial pressure (MAP), systolic pressure (SBP) and diastolic pressure (DBP) values. The SBP and DBP values were computed with characteristic ratio method. Wrist cuff waveforms were used for the emulation of auscultatory measurement of SBP and for the determination of stroke volume. Stroke volume, heart rate, cardiac output, total peripheral resistance, and systemic arterial compliance were computed. The obtained dual-cuff blood pressure values were compared with values measured by the characteristic ratio arm cuff method. The computed hemodynamics variables were displayed numerically and graphically.
Název v anglickém jazyce
Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination
Popis výsledku anglicky
This paper describes a method that uses two cuffs to improve accuracy of blood pressure and hemodynamics estimation. A specially designed dual-cuff experimental system was used to acquire and process data from the two cuffs. The arm cuff provided cuff pressures and cuff arterial pulse waveforms. The arm cuff pulse pressure waveforms were used to compute mean arterial pressure (MAP), systolic pressure (SBP) and diastolic pressure (DBP) values. The SBP and DBP values were computed with characteristic ratio method. Wrist cuff waveforms were used for the emulation of auscultatory measurement of SBP and for the determination of stroke volume. Stroke volume, heart rate, cardiac output, total peripheral resistance, and systemic arterial compliance were computed. The obtained dual-cuff blood pressure values were compared with values measured by the characteristic ratio arm cuff method. The computed hemodynamics variables were displayed numerically and graphically.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
RECENT RESEARCHES in MEDICINE and MEDICAL CHEMISTRY
ISBN
978-1-61804-111-1
ISSN
1790-5125
e-ISSN
—
Počet stran výsledku
6
Strana od-do
37-42
Název nakladatele
WSEAS Press
Místo vydání
Athens
Místo konání akce
KOS - Greece
Datum konání akce
14. 7. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—