Ensuring the operation of electrical equipment during short-time voltage sags or power outage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43925930" target="_blank" >RIV/49777513:23220/15:43925930 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7309293&newsearch=true&queryText=Ensuring%20the%20operation%20of%20electrical%20equipment%20during%20short-time%20voltage%20sags%20or%20power%20outage" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7309293&newsearch=true&queryText=Ensuring%20the%20operation%20of%20electrical%20equipment%20during%20short-time%20voltage%20sags%20or%20power%20outage</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2015.7309293" target="_blank" >10.1109/EPE.2015.7309293</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ensuring the operation of electrical equipment during short-time voltage sags or power outage
Popis výsledku v původním jazyce
This paper describes the situation of a modern electric drive (induction machine supplied from indirect frequency converter with voltage source inverter) in industry (paper mills, etc.), where a voltage sag can bring significant problems with long-time interruption of the production process. One method of operation is a direct increase of voltage in the DC-link of a frequency converter with a step-up converter during voltage sag. A transistor designed for braking is often used. It is used often presenttransistor designed for braking. The article presents the waveforms of voltages and currents in the circuit of an indirect frequency converter in the case of voltage sags without the intervention of a stepup converter. Then it presents waveforms with theuse of a boost converter and its various control options.
Název v anglickém jazyce
Ensuring the operation of electrical equipment during short-time voltage sags or power outage
Popis výsledku anglicky
This paper describes the situation of a modern electric drive (induction machine supplied from indirect frequency converter with voltage source inverter) in industry (paper mills, etc.), where a voltage sag can bring significant problems with long-time interruption of the production process. One method of operation is a direct increase of voltage in the DC-link of a frequency converter with a step-up converter during voltage sag. A transistor designed for braking is often used. It is used often presenttransistor designed for braking. The article presents the waveforms of voltages and currents in the circuit of an indirect frequency converter in the case of voltage sags without the intervention of a stepup converter. Then it presents waveforms with theuse of a boost converter and its various control options.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 17th European Conference on Power Electronics and Application (EPE ECCE Europe 2015)
ISBN
978-90-75815-23-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
1-8
Název nakladatele
IEEE
Místo vydání
Piscataway, New Jersey
Místo konání akce
Ženeva, Švýcarsko
Datum konání akce
8. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—