Partial discharges under DC voltage in paper-oil insulating system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43925977" target="_blank" >RIV/49777513:23220/15:43925977 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7295302" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7295302</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICPADM.2015.7295302" target="_blank" >10.1109/ICPADM.2015.7295302</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Partial discharges under DC voltage in paper-oil insulating system
Popis výsledku v původním jazyce
Partial discharges proved to be important diagnostic parameter during technical lifetime of operated electrical machines. Until now PD phenomena was well described and understood in technical society, espacially for characteristic arrangement, e. g. corona, tip to plane, sphere to plane, and others. Most of the studies were done under AC voltage. However as DC transmission is concerned, more attention must be paid to electrical field secondary effects. At DC voltage, space charge is formed and electrical field distribution is deformed. Hence description of PD behavior under AC can not be directly applied to DC voltage. Furthermore, DC PD phenomena is strongly dependent on voltage polarity, hence negative polarity is inparticular arrangements similar toAC PD behavior, while DC positive polarity behaves differently. For deeper understanding of PD phenomena under DC voltage, laboratory experiments were performed and compared. Tested specimen were samples of paper-oil insulating system, w
Název v anglickém jazyce
Partial discharges under DC voltage in paper-oil insulating system
Popis výsledku anglicky
Partial discharges proved to be important diagnostic parameter during technical lifetime of operated electrical machines. Until now PD phenomena was well described and understood in technical society, espacially for characteristic arrangement, e. g. corona, tip to plane, sphere to plane, and others. Most of the studies were done under AC voltage. However as DC transmission is concerned, more attention must be paid to electrical field secondary effects. At DC voltage, space charge is formed and electrical field distribution is deformed. Hence description of PD behavior under AC can not be directly applied to DC voltage. Furthermore, DC PD phenomena is strongly dependent on voltage polarity, hence negative polarity is inparticular arrangements similar toAC PD behavior, while DC positive polarity behaves differently. For deeper understanding of PD phenomena under DC voltage, laboratory experiments were performed and compared. Tested specimen were samples of paper-oil insulating system, w
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Conference on the Properties and Applications of Dielectric Materials (ICPADM 2015)
ISBN
978-1-4799-8903-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
436-439
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Sydney, Austrálie
Datum konání akce
19. 7. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—