Aspects of PD measurement in hybrid gaseous insulation at DC voltage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F16%3A43930799" target="_blank" >RIV/49777513:23220/16:43930799 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7757976/" target="_blank" >http://ieeexplore.ieee.org/document/7757976/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CMD.2016.7757976" target="_blank" >10.1109/CMD.2016.7757976</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Aspects of PD measurement in hybrid gaseous insulation at DC voltage
Popis výsledku v původním jazyce
The increased application of HVDC components in electrical energy systems has led to new challenges in diagnostic testing and measurement of electrical insulation. This paper deals with PD measurement on hybrid gaseous insulation at DC testing. Such insulation types are mostly characterized by the presence of insulating (solid) materials which become electrically charged, if an electric field is present within the insulation. For the study of such phenomena, a simple needle-plane electrode set with an insulating sheet was investigated at DC voltage with different polarities and electrical stress durations. It could be shown, that the charging process on the insulating sheet already takes place at test voltages below the measured PD inception voltage level. The charge intensity on that interface and, as a consequence, its impact on the electrical field conditions e.g. the inception field strength, depends both on polarity and applied voltage duration. It is assumed, that any charging process below the (self-sustaining) ionisation level, characterized by the electrical inception field strength, should be caused by natural ionisation processes which take place in the test object. This assumption was supported by different results obtained if the test set was under open- and closed- volume condition. In the same manner, the results obtained were confirmed by electrical field calculations for different charging conditions on the insulating sheet and applied voltage polarity. The results described in the paper lead to the main conclusion that the charging ability of interfaces in hybrid gaseous insulation must be considered if PD measurement at DC voltage should be performed.
Název v anglickém jazyce
Aspects of PD measurement in hybrid gaseous insulation at DC voltage
Popis výsledku anglicky
The increased application of HVDC components in electrical energy systems has led to new challenges in diagnostic testing and measurement of electrical insulation. This paper deals with PD measurement on hybrid gaseous insulation at DC testing. Such insulation types are mostly characterized by the presence of insulating (solid) materials which become electrically charged, if an electric field is present within the insulation. For the study of such phenomena, a simple needle-plane electrode set with an insulating sheet was investigated at DC voltage with different polarities and electrical stress durations. It could be shown, that the charging process on the insulating sheet already takes place at test voltages below the measured PD inception voltage level. The charge intensity on that interface and, as a consequence, its impact on the electrical field conditions e.g. the inception field strength, depends both on polarity and applied voltage duration. It is assumed, that any charging process below the (self-sustaining) ionisation level, characterized by the electrical inception field strength, should be caused by natural ionisation processes which take place in the test object. This assumption was supported by different results obtained if the test set was under open- and closed- volume condition. In the same manner, the results obtained were confirmed by electrical field calculations for different charging conditions on the insulating sheet and applied voltage polarity. The results described in the paper lead to the main conclusion that the charging ability of interfaces in hybrid gaseous insulation must be considered if PD measurement at DC voltage should be performed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CMD 2016: International Conference on Condition Monitoring and Diagnosis : (proceedings)
ISBN
978-1-5090-3398-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
932-937
Název nakladatele
Piscataway
Místo vydání
IEEE
Místo konání akce
Xi'an, China
Datum konání akce
25. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000390594000220