Dielectric behaviour of gaseous insulation with synthetic air at AC stress
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F16%3A43928869" target="_blank" >RIV/49777513:23220/16:43928869 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7521740/" target="_blank" >http://ieeexplore.ieee.org/document/7521740/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2016.7521740" target="_blank" >10.1109/EPE.2016.7521740</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dielectric behaviour of gaseous insulation with synthetic air at AC stress
Popis výsledku v původním jazyce
The paper deals with basic investigation of AC breakdown behaviour of gaseous insulation with synthetic air at different level of field homogeneity and gas pressure. The measurement was performed at different gas pressure ranging from 0.1 to 0.25 MPa and gap distances from 1 to 9 cm, using an electrode test-set "tip - bowl". The test parameters were chosen in such a way that different field types could be realized. At small distances the electrical field is weakly inhomogeneous and the breakdown values correspond to the discharge inception level. The measured values show a reasonable agreement to those values based on the calculation of the streamer criterion by using a relevant approximation formula for the effective ionisation coefficient. For larger distances the electrical field becomes more inhomogeneous and the calculated streamer inception voltage corresponds to the partial discharge (PD) inception voltage only. The calculated inception voltage values fit the measured values over the applied gap distance and gas pressure quite sufficiently. The best fit to the measured results was reached by slightly changing the parameters of the approximation formula depending on the gas pressure value. Additional PD measurement shows different PD activity dependent on gas pressure and gap distance.
Název v anglickém jazyce
Dielectric behaviour of gaseous insulation with synthetic air at AC stress
Popis výsledku anglicky
The paper deals with basic investigation of AC breakdown behaviour of gaseous insulation with synthetic air at different level of field homogeneity and gas pressure. The measurement was performed at different gas pressure ranging from 0.1 to 0.25 MPa and gap distances from 1 to 9 cm, using an electrode test-set "tip - bowl". The test parameters were chosen in such a way that different field types could be realized. At small distances the electrical field is weakly inhomogeneous and the breakdown values correspond to the discharge inception level. The measured values show a reasonable agreement to those values based on the calculation of the streamer criterion by using a relevant approximation formula for the effective ionisation coefficient. For larger distances the electrical field becomes more inhomogeneous and the calculated streamer inception voltage corresponds to the partial discharge (PD) inception voltage only. The calculated inception voltage values fit the measured values over the applied gap distance and gas pressure quite sufficiently. The best fit to the measured results was reached by slightly changing the parameters of the approximation formula depending on the gas pressure value. Additional PD measurement shows different PD activity dependent on gas pressure and gap distance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2016 17th International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-5090-0907-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
325-329
Název nakladatele
Czech Technical University in Prague
Místo vydání
Prague
Místo konání akce
Praha, Česká republika
Datum konání akce
16. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000382934600026