Breakdown behaviour with respect to the impact of technological failures in synthetic air insulated systems_report 2019_part A .-0001-5900000799
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F19%3A43957875" target="_blank" >RIV/49777513:23220/19:43957875 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Breakdown behaviour with respect to the impact of technological failures in synthetic air insulated systems_report 2019_part A .-0001-5900000799
Popis výsledku v původním jazyce
In previous research co-operation between SE and ZCU numerous tests have been performed to describe and predict the dielectric breakdown behavior in synthetic air gas insulation between generic geometries representative for ideal medium voltage switchgear design elements. Concerning the practical industrial manufacturing of GIS one next step in research was performed, to investigate the impact of defects like protrusions caused by technological imperfects. The obtained results should be valuable for proper designed GIS equipment in manufacturing and quality testing. In the given report the obtained results at lightning impulse stress voltage will be described.
Název v anglickém jazyce
Breakdown behaviour with respect to the impact of technological failures in synthetic air insulated systems_report 2019_part A .-0001-5900000799
Popis výsledku anglicky
In previous research co-operation between SE and ZCU numerous tests have been performed to describe and predict the dielectric breakdown behavior in synthetic air gas insulation between generic geometries representative for ideal medium voltage switchgear design elements. Concerning the practical industrial manufacturing of GIS one next step in research was performed, to investigate the impact of defects like protrusions caused by technological imperfects. The obtained results should be valuable for proper designed GIS equipment in manufacturing and quality testing. In the given report the obtained results at lightning impulse stress voltage will be described.
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Počet stran výsledku
23
Místo vydání
—
Název nakladatele resp. objednatele
Schneider Electric Sachsenwerk GmbH
Verze
—