Breakdown Behaviour at Synthetic Air Insulated System Composed with Solid Interface
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F21%3A43961937" target="_blank" >RIV/49777513:23220/21:43961937 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Breakdown Behaviour at Synthetic Air Insulated System Composed with Solid Interface
Popis výsledku v původním jazyce
In previous research co-operation between SE and ZCU numerous tests have been performed to describe and predict the dielectric breakdown behaviour in synthetic air gas insulation. Further investigation was focused on issues related to practical industrial manufacturing of GIS. All those investigations were performed in pure gaseous insulation arrangements. On the other hand at a practical designed GIS some interfaces of insulating materials are existing. In particular, the impact of barriers on breakdown proces is of great practical importance for proper designed equipment in manufacturing and quality testing. Therefore, first investigation of an impact of such dielectric interfaces on breakdown behavior was carried out. At first an appropriate test arrangement for the mentioned target was designed and manufactured. After that the test set was stressed at lightning impulse voltage as well as under 50 Hz AC conditions
Název v anglickém jazyce
Breakdown Behaviour at Synthetic Air Insulated System Composed with Solid Interface
Popis výsledku anglicky
In previous research co-operation between SE and ZCU numerous tests have been performed to describe and predict the dielectric breakdown behaviour in synthetic air gas insulation. Further investigation was focused on issues related to practical industrial manufacturing of GIS. All those investigations were performed in pure gaseous insulation arrangements. On the other hand at a practical designed GIS some interfaces of insulating materials are existing. In particular, the impact of barriers on breakdown proces is of great practical importance for proper designed equipment in manufacturing and quality testing. Therefore, first investigation of an impact of such dielectric interfaces on breakdown behavior was carried out. At first an appropriate test arrangement for the mentioned target was designed and manufactured. After that the test set was stressed at lightning impulse voltage as well as under 50 Hz AC conditions
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Počet stran výsledku
1
Místo vydání
—
Název nakladatele resp. objednatele
Schneider Electric Industries SAS
Verze
—